Opening the book…
A battery lifts charge to a higher potential, and a resistor lets it fall again. As charge \(dQ\) passes through a circuit element across which the potential drops by \(V\), its potential energy falls by \(dQ\,V\) (Section 18.1). In a resistor, that energy does not become kinetic energy of the carriers: their drift speed stays the same all along the wire. Instead, it goes into the collisions with the ions, making them vibrate more and heating the material. The rate at which the energy is delivered is
\[P = \frac{dU}{dt} = \frac{dQ}{dt}V,\]
and so the electrical power delivered to any circuit element is
Key Equation: Electrical power
\[P = IV. \tag{20.10}\]
This holds for any device, whether a resistor, a motor, a charging battery, or a lamp: current times potential difference is power, in watts, since \((1\,\mathrm{C/s})(1\,\mathrm{J/C}) = 1\,\mathrm{J/s} = 1\,\mathrm{W}\). For a resistor, using \(V = IR\), the power dissipated as heat can be written in two more ways:
Key Equation: Power dissipated in a resistor
\[P = I^2R = \frac{V^2}{R}. \tag{20.11}\]
This heating is called Joule heating. It is exactly what a toaster, an electric kettle, or a space heater is designed to do, and it is an unwanted loss in wires, transformers, and electronic circuits, which is why computers need fans.
Electric utilities bill for energy, not power, in kilowatt-hours (kWh): the energy delivered in one hour at a power of one kilowatt, \(1\,\mathrm{kWh} = (1000\,\mathrm{W})(3600\,\mathrm{s}) = 3.6\times 10^{6}\,\mathrm{J}\).
Example 20.9: A space heater
A space heater is rated at \(1500\,\mathrm{W}\) on a \(120\,\mathrm{V}\) circuit. (a) What current does it draw, and what is its resistance when hot? (b) If it runs \(6.0\,\mathrm{h}\) a day for a \(30\)-day month, and electrical energy costs \(\$0.30\) per kWh, what does it cost to run?
Solution
(a) \(I = P/V = 1500/120 = \boxed{12.5\,\mathrm{A}}\), and \(R = V/I = 120/12.5 = \boxed{9.6\,\mathrm{\Omega}}\) (or \(R = V^2/P\)). That is most of the capacity of a typical \(15\,\mathrm{A}\) household circuit, which is why running a heater and a hair dryer on the same circuit trips the breaker.
(b) The energy used is \((1.5\,\mathrm{kW})(6.0\,\mathrm{h/day})(30\,\mathrm{days}) = 270\,\mathrm{kWh}\), costing \((270)(\$0.30) = \boxed{\$81}\).
Example 20.10: Why power lines use high voltage
A power plant sends \(100\,\mathrm{MW}\) to a city through transmission lines with a total resistance of \(5.0\,\mathrm{\Omega}\). Find the power lost as heat in the lines if the power is transmitted at (a) \(10\,\mathrm{kV}\) and (b) \(500\,\mathrm{kV}\).
Solution
The current in the lines is \(I = P/V\), and the power lost in them is \(P_{\text{loss}} = I^2R\).
(a) At \(10\,\mathrm{kV}\), \(I = (100\times10^{6})/(10\times10^{3}) = 1.0\times 10^{4}\,\mathrm{A}\), and
\[P_{\text{loss}} = (1.0\times10^{4})^2(5.0) = \boxed{5.0\times 10^{8}\,\mathrm{W}},\]
five times the power being sent. This is impossible in practice: the lines would melt long before delivering anything.
(b) At \(500\,\mathrm{kV}\), \(I = 200\,\mathrm{A}\), and
\[P_{\text{loss}} = (200)^2(5.0) = \boxed{2.0\times 10^{5}\,\mathrm{W}},\]
only \(0.2\%\) of the power sent. Because the loss goes as \(I^2\), raising the voltage fifty times cuts the loss by a factor of \(2500\). This is why long-distance lines run at hundreds of thousands of volts, and why the transformers of Chapter 25 are needed to step the voltage up for transmission and back down for use in the home.
Note: \(P = I^2R\) or \(P = V^2/R\)?
The two formulas look contradictory: one says power grows with resistance, the other that it falls. Both are right; they answer different questions. For resistors carrying the same current, as in the transmission line, more resistance means more heating, \(P = I^2R\). For resistors connected to the same voltage, as for appliances plugged into the same outlet, less resistance means more current and more heating, \(P = V^2/R\). A \(100\,\mathrm{W}\) bulb has less resistance than a \(60\,\mathrm{W}\) bulb.
Checkpoint 20.4
A \(60\,\mathrm{W}\) and a \(100\,\mathrm{W}\) bulb are both designed for \(120\,\mathrm{V}\). (a) Which has the greater resistance? (b) Which draws more current when plugged in normally? (c) What happens to the power of the \(100\,\mathrm{W}\) bulb if it is run on \(60\,\mathrm{V}\), assuming its resistance stays the same?
Answers to Checkpoints
Checkpoint 20.4. (a) From \(P = V^2/R\), \(R = V^2/P\), so the lower-power bulb has the greater resistance: \((120)^2/60 = 240\,\mathrm{\Omega}\) versus \((120)^2/100 = 144\,\mathrm{\Omega}\). (b) The \(100\,\mathrm{W}\) bulb, since \(I = P/V\): \(0.83\,\mathrm{A}\) versus \(0.50\,\mathrm{A}\). (c) At fixed resistance, \(P = V^2/R\) scales as \(V^2\), so halving the voltage cuts the power to a quarter: \(25\,\mathrm{W}\). (In reality the cooler filament’s resistance would drop somewhat, so the bulb would draw a little more than this.)
This page titled 20.4: Electrical Power was last modified on Thu, 12 Nov 2026 04:27:00 GMT and is shared under a CC BY 4.0 license and was authored, remixed, and/or curated by Michael Ragsdale.