Rayleigh flow describes steady, one-dimensional, frictionless flow of a perfect gas through a constant-area duct with heat transfer as shown in Figure 2. It is a model for combustion chambers, afterburners and ramjet combustors, where the dominant effect is heat addition rather than area change or friction.
Its main features are:
- Heat addition drives the flow toward \(Ma = 1\) adding heat to a subsonic flow accelerates it. Adding heat to a supersonic flow decelerates it. Either way the Mach number approaches 1.
- Thermal choking, once \(Ma = 1\) is reached, no more heat can be added without changing the upstream conditions. This sets the maximum heat input for a given inlet state.
- Cooling has the opposite effect; it moves the flow away from \(Ma = 1\).
- Adding heat to a flowing fluid causes a irreversible drop in total (stagnation) pressure (\(p_0\)), often referred to as fundamental pressure loss or Rayleigh loss, even in the complete absence of wall friction.
2.2.1 Governing Conservation Equations
For uniform, frictionless flow of a perfect gas in a constant-area duct with heat transfer rate \(\dot{Q}\):
- Continuity Equation: \[\rho_1 u_1=\rho_2 u_2 \nonumber \]
- Momentum Equation:\[p_1+{\rho }_1u^2_1=p_2+{\rho }_2u^2_2\Longrightarrow I_1=I_2 \nonumber \]
In Rayleigh flow, the fluid impulse function \(I\) remains constant along the flow direction due to the frictionless assumption. Accounting for heat transfer across the duct boundary, the energy balance for the fluid is expressed as:
\[\dot{m}\left(h_{t2}-h_{t1}\right)=\dot{Q} \nonumber \]
Because mass flow rate (\(\dot{m}\)) acts as a scaling parameter, dividing the equation by \(\dot{m}\) yields the heat input per unit mass, defined as \(q=\dot{Q}/\dot{m}\):
\[h_{t2}=h_{t1}+q \nonumber \]
Thus, given the entry total enthalpy \(h_{t1}\) and the specific heat addition \(q\), the exit total enthalpy \(h_{t2}\) can be determined directly. Rayleigh flow shares identical conservation of mass and momentum relations with standard normal shock waves; it differs solely through the addition of the thermal energy term in the energy equation.
Relating static pressures across the region using the momentum equation gives:
\[\dfrac{p_2}{p_1}=\dfrac{1+kMa^2_1}{1+kMa^2_2} \nonumber \]
From mass conservation, the density ratio can be expressed in terms of Mach numbers and static temperatures:
\[\frac{\rho_2}{\rho_1}=\frac{u_1}{u_2}=\dfrac{Ma_1 a_1}{Ma_2 a_2}=\frac{Ma_1}{Ma_2}\sqrt{\frac{T_1}{T_2}} \nonumber \]
Applying the ideal gas state equation (\(\rho =p/RT\)) allows the density ratio to be replaced by pressure and temperature ratios:
\[\frac{p_2}{p_1}\left(\frac{T_1}{T_2}\right)=\left(\frac{1+k M a_1^2}{1+k M a_2^2}\right)\left(\frac{T_1}{T_2}\right)=\frac{M a_1}{M a_2} \sqrt{\frac{T_1}{T_2}} \nonumber \]
Rearranging this relationship yields the static temperature ratio across the state change:
\[\frac{T_2}{T_1}={\left(\frac{{Ma}_2}{{Ma}_1}\right)}^2{\left(\frac{1+k{Ma}^2_1}{1+k{Ma}^2_2}\right)}^2 \nonumber \]
Since density is proportional to pressure divided by temperature, combining the pressure and temperature ratio expressions yields the density ratio:
\[\frac{{\rho }_2}{{\rho }_1}=\frac{p_2/p_1}{T_2/T_1}={\left(\frac{{Ma}_1}{{Ma}_2}\right)}^2\left(\frac{1+k{Ma}^2_2}{1+k{Ma}^2_1}\right) \nonumber \]
This formulation links all downstream thermodynamic properties directly to the upstream conditions and the inlet and outlet Mach numbers. The unknown exit Mach number can then be evaluated using the energy relation.
Thermodynamic Relations & Gibbs Equation
Next, we can evaluate the thermodynamic behavior of the flow along a T-s diagram (Figure 3), commonly referred to as the Rayleigh line. We begin with the Gibbs equation in differential form:
\[ds=c_p\frac{dT}{T}-R\frac{dp}{p} \nonumber \]
From conservation of momentum, the relationship between static pressure and Mach number remains constant across the process:
\[p\left(1+k{Ma}^2\right)=\mathrm{constant} \nonumber \]
Taking the logarithmic derivative of this momentum expression yields a differential relation between relative pressure changes and variations in Mach number:
\[\frac{dp}{p}+\frac{2kMa\ dMa}{1+k{Ma}^2}=0 \nonumber \]
By replacing the incremental pressure ratio as a function of \(dMa/Ma\) into the differential entropy equation, we obtain:
\[ds=c_p\frac{dT}{T}+R\left(\frac{2k{Ma}^2}{1+k{Ma}^2}\right)\frac{dMa}{Ma} \label{eq1}\]
Next, consider the differential form of the mass conservation (continuity) equation:
\[\frac{d\rho }{\rho }+\frac{du}{u}=0 \nonumber \]
Applying the ideal gas law (\(p=\rho RT\)) along with the Mach number relation (\(u=Ma\sqrt{kRT}\)), we can rewrite the density variation in terms of pressure, temperature, and Mach number:
\[\frac{dp}{p}-\frac{dT}{T}+\frac{dMa}{Ma}+\frac{dT}{2T}=\frac{dp}{p}-\frac{dT}{2T}+\frac{dMa}{Ma}=0 \nonumber \]
Integrating the momentum differential equation allows us to link changes in static temperature (\(dT\)) directly to Mach number variations:
\[\frac{dMa}{Ma}=\frac{1}{2}\frac{dT}{T}+\left(\frac{2k{Ma}^2}{1+k{Ma}^2}\right)\frac{dMa}{Ma} \nonumber \]
Rearranging terms yields a direct relationship between \(dMa/Ma\) and \(dT/T\):
\[\frac{dMa}{Ma}=\left(\frac{dT}{2T}\right)\left(\frac{1+k{Ma}^2}{1-k{Ma}^2}\right) \label{eq4b} \]
Substituting Equation \ref{eq4b} back into the entropy relation Equation \ref{eq1} produces:
\[ds=c_p\frac{dT}{T}+R\left(\frac{2k{Ma}^2}{1+k{Ma}^2}\right)\left[\frac{1}{2}\frac{dT}{T}\left(\frac{1+k{Ma}^2}{1-k{Ma}^2}\right)\right]=c_p\frac{dT}{T}\left[1+\left(k-1\right)\left(\frac{{Ma}^2}{1-k{Ma}^2}\right)\right] \nonumber \]
Factoring out the temperature gradient gives the final expression for entropy variation along a Rayleigh line as a function of \(T\) and local Mach number \(Ma\):
\[ds=c_p\left(\frac{1-{Ma}^2}{1-k{Ma}^2}\right)\frac{dT}{T} \nonumber \]
The \(T-s\) Rayleigh curve as indicated in Figure 3:
- Setting \(\frac{ds}{dT}=0\) identifies the state of maximum entropy (occurring at \(Ma=1\)).
- Setting \(\frac{dT}{ds}=0\) locates the state of maximum static temperature (occurring at \(Ma=1/\sqrt{k}\)).

The Rayleigh curve comprises subsonic and supersonic branches that converge at the sonic point (\(Ma=1\)). Energy addition pushes both speed regimes toward thermal choking, whereas heat extraction shifts the flow away from \(Ma=1\)—reducing velocity in subsonic regimes and increasing it in supersonic ones. Static temperature peaks prior to sonic conditions, occurring specifically at \(Ma=1/\sqrt{k}\). Past this threshold, further heat input decreases static temperature even as the flow continues accelerating toward \(Ma=1\); total (stagnation) temperature, however, increases monotonically with heat addition. The maximum heat input required to choke the exit (\({Ma}_e=1\)) is defined as the critical thermal input, \(q^*\). Because maximum entropy aligns precisely with \(Ma=1\), sonic flow can only be attained at the duct’s exit boundary.
Graphically, the Rayleigh line represents all thermodynamic states sharing a constant mass flux (\(\dot{m}/A=ρu\)). Because the energy equation is omitted when constructing the \(T\)-\(s\) diagram for Rayleigh flow, its governing momentum balance matches that of a normal shock wave—meaning a normal shock transition connects two points along the same Rayleigh curve. Because wall friction is neglected, heat transfer processes along the Rayleigh line are internally reversible. Consequently, the area beneath the curve on a \(T\)-\(s\) diagram, as seen in Figure 4, directly quantifies heat transfer per unit mass (\(\int{T}\ ds\)). Heating a subsonic entry state drives it along the lower branch toward higher entropy and Mach numbers, eventually reaching the limiting sonic state.
- Subsonic Branch (\(Ma<1\)): Adding heat accelerates the flow toward \(Ma=1\). Between \(Ma=1/\sqrt{k}\) and \(Ma=1\), heating causes static temperature \(T\) to decrease while total temperature \(T_t\) continues to rise.
- Supersonic Branch (\(Ma>1\)): Adding heat decelerates the flow toward \(Ma=1\).
- Thermal Choking: Heating a flow to the point where the exit reaches \(Ma=1\) defines the maximum allowable heat addition, termed the critical heating rate (\(q^*\)). Any heat input exceeding \(q^*\) alters the inlet conditions (reducing inlet mass flow rate or causing flow spillage).
Adding the maximum allowable thermal energy, \(q^*\), drives the duct exit to a choked condition (\(Ma=1\)). Because adding heat to a supersonic stream reduces its velocity, scramjet combustors face an operational threshold: exceeding a specific fuel delivery rate will force the combustion chamber exit to choke. Additional details on supersonic burning processes are discussed later in this text. The magnitude of this critical heat input \(q^*\) depends directly on the initial state of the incoming gas. If thermal addition exceeds \(q^*\), the system can no longer maintain its original inlet conditions and must adjust by throttling the incoming mass flow. This behavior is represented on a T-s diagram by a set of Rayleigh curves corresponding to progressively lower mass flux values.
This page titled 2.2: Rayleigh flow was last modified on Wed, 18 Nov 2026 07:18:34 GMT and is shared under a CC BY 4.0 license and was authored, remixed, and/or curated by .
The book could not be loaded just now.