    32.5: Optical Instruments

    The rule of Section 32.4 (one optic at a time, each image the object for the next) is all it takes to understand the instruments that extend human sight. We begin with the instrument every one of them is built to serve, the eye, and then look at the magnifying glass, the microscope, and the two kinds of telescope.

    The eye

    The eye is a camera. Light enters through the clear, curved cornea, passes through the pupil, and is focused by the lens onto the retina, a light-sensitive layer at the back of the eyeball (Figure 32.9a). Most of the bending happens at the cornea, where light passes from air into the watery eye; the lens supplies the adjustable remainder. The image on the retina is real and inverted, and the brain simply interprets it the right way up.

    Unlike a camera, the eye cannot move its lens to focus: the distance from lens to retina is fixed at about \(2\,\mathrm{cm}\). Instead, small muscles change the shape of the lens, and so its focal length. This is accommodation. Relaxed, the lens is at its flattest and a normal eye focuses distant objects. Tensed, the lens bulges and focuses nearer ones. The nearest point the eye can bring into focus is its near point; for a young adult it is about \(25\,\mathrm{cm}\), the standard value used in optics. The farthest is the far point, at infinity for a normal eye.

    Four panels, each showing an eye in side view with light arriving from the left.
    Figure 32.9. Common focusing problems and their correction. (a) A nearsighted eye focuses distant objects in front of the retina, so they look blurred. (b) A diverging lens spreads the incoming rays just enough that the eye focuses them on the retina. (c) A farsighted eye cannot bend the rays from a nearby object strongly enough; they would focus behind the retina. (d) A converging lens supplies the missing bending.
    Figure descriptionFour panels, each showing an eye in side view with light arriving from the left. The eye is a circle with a bulging cornea at the front, a lens just behind it, and the retina drawn thick along the back. Panel a, nearsighted, uncorrected: three parallel rays from a distant object are focused to a point in front of the retina and have spread apart again by the time they reach it, so the image is blurred. Panel b, nearsighted, corrected: a diverging lens in front of the eye spreads the parallel rays slightly, and the eye now focuses them exactly on the retina. Panel c, farsighted, uncorrected: rays spreading from a nearby point object are aimed at a focus behind the retina, so they are still spread out when they reach it. Panel d, farsighted, corrected: a converging lens in front of the eye makes the rays spread less, and the eye now focuses them on the retina.

    When the eye’s power does not match its length, vision blurs (Figure 32.9).

    • A nearsighted (myopic) eye bends light too strongly for its length. Distant objects come to a focus in front of the retina, and the far point is closer than infinity. A diverging lens corrects it.
    • A farsighted (hyperopic) eye bends light too weakly. Its near point is farther than \(25\,\mathrm{cm}\), so nearby objects blur. A converging lens corrects it.
    • With age the lens stiffens and accommodation weakens, so the near point recedes even in an otherwise normal eye. This is presbyopia, the reason most people need reading glasses after about age 45.

    The strategy for choosing a corrective lens is always the same: the lens takes an object at the distance the person wants to see and forms a virtual image at a distance the person’s eye can see. The eye then looks at that image instead.

    Optometrists describe a lens not by its focal length but by its power,

    Key Equation: Power of a lens

    \[P = \frac{1}{f} \qquad (f \text{ in meters, } P \text{ in diopters, } 1\,\mathrm{D} = 1\,\mathrm{m^{-1}}). \tag{32.7}\]

    A converging lens has positive power and a diverging lens negative power, so the sign on a prescription tells you at a glance which problem is being corrected. A strong lens (short focal length) has a large power, and for thin lenses placed close together the powers simply add.

    Example 32.5: Prescribing corrective lenses

    Treat each corrective lens as sitting right at the eye (a contact lens).

    1. A nearsighted student has a far point of \(40\,\mathrm{cm}\). What power of lens lets her see distant objects clearly?
    2. A farsighted student has a near point of \(1.0\,\mathrm{m}\). What power of lens lets him read a book held \(25\,\mathrm{cm}\) away?
    Solution

    (a) The lens must take an object at infinity and form a virtual image at the far point, \(i = -0.40\,\mathrm{m}\):

    \[P = \frac{1}{f} = \frac{1}{p} + \frac{1}{i} = \frac{1}{\infty} + \frac{1}{-0.40\,\mathrm{m}} = \boxed{-2.5\,\mathrm{D}}.\]

    A diverging lens of focal length \(-40\,\mathrm{cm}\), as expected for nearsightedness.

    (b) The lens must take an object at \(p = 0.25\,\mathrm{m}\) and form a virtual image at the near point, \(i = -1.0\,\mathrm{m}\):

    \[P = \frac{1}{0.25\,\mathrm{m}} + \frac{1}{-1.0\,\mathrm{m}} = 4.0 - 1.0 = \boxed{+3.0\,\mathrm{D}}.\]

    A converging lens of focal length \(33\,\mathrm{cm}\).

    Angular magnification and the magnifying glass

    How large something looks is set not by its actual size but by the angle it spans at your eye, because that angle fixes the size of its image on the retina. A coin at arm’s length looks bigger than the Moon. To see detail you bring an object closer, which enlarges the angle, but only as far as your near point. At the near point \(N = 25\,\mathrm{cm}\), an object of height \(h\) spans the angle

    \[\theta \approx \frac{h}{N}.\]

    Now hold a converging lens of focal length \(f\) in front of your eye and put the object at its focal point (Figure 32.10). The rays from each point of the object leave the lens parallel, so the image is at infinity and your eye views it fully relaxed. A ray from the top of the object through the center of the lens shows that it now spans the angle \(\theta' \approx h/f\). Because a magnifier’s job is to enlarge an angle, it is rated by its angular magnification rather than by the image-size ratio \(m\):

    Key Equation: Angular magnification of a simple magnifier

    \[M = \frac{\theta'}{\theta} \approx \frac{N}{f} = \frac{25\,\mathrm{cm}}{f} \qquad \text{(image at infinity, relaxed eye)}. \tag{32.8}\]

    A lens of focal length \(5\,\mathrm{cm}\) is a \(5\times\) magnifier. (Moving the object slightly inside the focal point, so that the virtual image of Figure 32.6 sits at the near point, raises this to \(1 + N/f\), at the cost of a tensed eye.)

    Two panels comparing how large an object looks.
    Figure 32.10. Angular magnification. (a) Unaided, the closest an object can be viewed sharply is the near point, where it spans \(\theta \approx h/N\). (b) With the object at the focal point of a converging lens held close to the eye, it spans \(\theta' \approx h/f\), and the rays leave the lens parallel so the relaxed eye sees it at infinity. The angular magnification is \(M = \theta'/\theta = N/f\).
    Figure descriptionTwo panels comparing how large an object looks. Panel a: an eye at the right views a small upright object at the left, a distance N equal to 25 centimeters away. A line from the top of the object to the eye makes a small angle theta with the axis. Panel b: a converging lens sits just in front of the same eye, and the object now stands at the lens's focal point, a distance f away. A ray from the top of the object through the center of the lens makes the larger angle theta prime with the axis, and a second ray leaves the lens parallel to it, toward the eye, showing that the image is at infinity.

    The compound microscope

    A single magnifier tops out at about \(10\times\) to \(20\times\), because a much shorter focal length means a tiny, badly distorting lens. A compound microscope gets far more by using two lenses in sequence (Figure 32.11). The objective, a lens of very short focal length \(f_o\), sits just beyond the specimen and forms a real, inverted, greatly enlarged intermediate image inside the tube. The eyepiece is then used as a magnifying glass to view that image, placed so the image falls at its focal point and the eye stays relaxed.

    The total magnification is the product of the two stages. The specimen sits just outside the objective’s focal point, and the intermediate image forms a distance \(L\), the tube length, beyond the objective’s far focal point. So \(i_o \approx L + f_o\), \(p_o \approx f_o\), and the objective’s magnification is \(m_o = -i_o/p_o \approx -L/f_o\). The eyepiece adds an angular magnification \(N/f_e\), giving

    Key Equation: Compound microscope

    \[M = m_o \times M_e \approx -\frac{L}{f_o}\,\frac{N}{f_e}, \qquad N = 25\,\mathrm{cm}. \tag{32.9}\]

    The negative sign records that the final view is inverted, which is why a slide seems to move the wrong way when you push it. Many microscopes use the standard tube length \(L = 160\,\mathrm{mm}\).

    A ray diagram of a compound microscope, not to scale.
    Figure 32.11. A compound microscope (not to scale). The objective forms a real, inverted, enlarged image a tube length \(L\) beyond its focal point. That image sits at the focal point of the eyepiece, which acts as a magnifying glass and sends parallel rays to the relaxed eye. The total magnification is \(M \approx -(L/f_o)(N/f_e)\).
    Figure descriptionA ray diagram of a compound microscope, not to scale. A small green specimen stands just to the left of the objective's focal point. Red rays from the top of the specimen pass through the objective, a short-focal-length lens, and meet far to the right at the tip of a large, inverted, real intermediate image. That image sits at the focal point of the eyepiece, a second lens further right. Gold rays from the tip of the intermediate image pass through the eyepiece and leave it parallel to each other, angled upward, toward the eye. The tube length L is marked between the objective's far focal point and the intermediate image.
    Example 32.6: A student microscope

    A microscope has an objective of focal length \(8.0\,\mathrm{mm}\), an eyepiece of focal length \(20\,\mathrm{mm}\), and a tube length of \(160\,\mathrm{mm}\). (a) Find the overall magnification. (b) How far in front of the objective must the specimen sit?

    Solution

    (a) The objective magnifies by \(m_o \approx -L/f_o = -160/8.0 = -20\), and the eyepiece by \(M_e = N/f_e = 250\,\mathrm{mm}/20\,\mathrm{mm} = 12.5\), so

    \[M \approx (-20)(12.5) = \boxed{-250}.\]

    The view is enlarged \(250\) times and inverted.

    (b) The intermediate image lies \(i_o = L + f_o = 168\,\mathrm{mm}\) beyond the objective. The thin-lens equation gives the object distance:

    \[\frac{1}{p_o} = \frac{1}{8.0} - \frac{1}{168} = 0.1190\,\mathrm{mm^{-1}}, \qquad p_o = \boxed{8.4\,\mathrm{mm}}.\]

    The specimen sits just \(0.4\,\mathrm{mm}\) outside the focal point, which is why a microscope’s focus knob moves in such tiny steps.

    Telescopes

    A telescope looks at objects so far away that their light arrives as parallel rays. Its objective therefore forms a small, real, inverted image at its focal point, and an eyepiece placed with its own focal point at the same spot views that image as a magnifier. The two lenses are separated by \(f_o + f_e\), and the rays leave the eyepiece parallel, so the eye is relaxed (Figure 32.12).

    A distant object spans some angle \(\theta\) at the telescope. The objective’s image of it, at distance \(f_o\), has height \(h \approx f_o\theta\); seen through the eyepiece, that image spans \(\theta' \approx h/f_e\). The angular magnification is therefore

    Key Equation: Angular magnification of a telescope

    \[M = \frac{\theta'}{\theta} = -\frac{f_o}{f_e}, \tag{32.10}\]

    negative because the view is inverted (a nuisance on Earth, irrelevant for stars). A long objective focal length and a short eyepiece focal length give high magnification, and switching eyepieces changes it.

    Refracting telescope: parallel rays through the objective and eyepiece, with angular magnification.
    Figure 32.12. A refracting telescope. Parallel light from a distant object, arriving at angle \(\theta\), is focused by the objective at its focal point, which is also the eyepiece’s focal point. The rays leave the eyepiece parallel again at the larger angle \(\theta'\); the angular magnification is \(M = -f_o/f_e\) (here \(-4\)).
    Figure descriptionA refracting telescope. Three parallel red rays from a distant object arrive from the left, angled slightly downward at angle theta. They pass through the objective lens and meet at a point a little below the axis, at the shared focal point of the objective and the eyepiece, a distance f sub o from the objective. They continue, spreading, to the eyepiece a distance f sub e further on, and leave it parallel again, now angled upward at the much larger angle theta prime.

    Magnification is not actually a telescope’s most important job. Most astronomical objects are faint, and the bigger the objective, the more light it collects: light gathered is proportional to the objective’s area, and so to the square of its diameter \(D\). A larger objective also blurs fine detail less, because diffraction (Chapter 34) sets a limit on resolution that improves as \(D\) grows.

    That push for larger objectives is why every major research telescope is a reflecting telescope, using a concave mirror instead of a lens as its objective. A lens bends different colors by slightly different amounts (dispersion: the index of refraction of glass depends slightly on wavelength), so it focuses each color at a slightly different point; a mirror reflects all colors alike. A lens must also be supported only at its rim and sags under its own weight, while a mirror can be supported across its entire back. The largest refracting telescope ever built for astronomy, at Yerkes Observatory, has a lens just over \(1\,\mathrm{m}\) across; the Hubble Space Telescope’s mirror is \(2.4\,\mathrm{m}\) across, and the James Webb Space Telescope’s primary mirror, made of 18 hexagonal segments, is \(6.5\,\mathrm{m}\) across.

    In Newton’s original design (Figure 32.13), the concave primary mirror at the back of the tube reflects the incoming light toward its focal point, and a small flat diagonal mirror near the front turns the converging beam out through the side of the tube to the eyepiece. The magnification is again \(M = -f_o/f_e\), with \(f_o = R/2\) the focal length of the primary mirror.

    A Newtonian reflecting telescope, drawn as a long tube open at the left end.
    Figure 32.13. A Newtonian reflecting telescope. The concave primary mirror is the objective. A small flat diagonal mirror redirects the converging light to an eyepiece on the side of the tube, where it is viewed exactly as in a refractor.
    Figure descriptionA Newtonian reflecting telescope, drawn as a long tube open at the left end. Two parallel red rays from a distant star enter the open end, pass on either side of a small flat diagonal mirror near the front, and travel the length of the tube to a concave primary mirror at the back. They reflect from it and converge back up the tube toward a focus, but before reaching it they strike the diagonal mirror, set at 45 degrees, which turns them upward to a focus just inside an eyepiece mounted on the side of the tube.
    Example 32.7: A backyard reflector

    An amateur’s Newtonian telescope has a primary mirror \(20.0\,\mathrm{cm}\) in diameter with a radius of curvature of \(2.40\,\mathrm{m}\). It comes with eyepieces of focal length \(25\,\mathrm{mm}\) and \(10\,\mathrm{mm}\). (a) Find the magnification with each eyepiece. (b) How many times more light does the mirror collect than a dark-adapted eye, whose pupil is about \(7.0\,\mathrm{mm}\) across?

    Solution

    (a) The primary mirror’s focal length is \(f_o = R/2 = 1.20\,\mathrm{m} = 1200\,\mathrm{mm}\). Then

    \[M_{25} = -\frac{1200\,\mathrm{mm}}{25\,\mathrm{mm}} = \boxed{-48}, \qquad M_{10} = -\frac{1200\,\mathrm{mm}}{10\,\mathrm{mm}} = \boxed{-120}.\]

    Swapping eyepieces is how an observer changes magnification.

    (b) Collected light is proportional to aperture area, so to the square of the diameter:

    \[\frac{D_{\rm mirror}^2}{D_{\rm pupil}^2} = \left(\frac{200\,\mathrm{mm}}{7.0\,\mathrm{mm}}\right)^2 = \boxed{816}.\]

    The telescope shows stars about 800 times fainter than the eye alone can see, whichever eyepiece is in place. That, more than magnification, is what a telescope is for.

    Checkpoint 32.5

    (a) An eyeglass prescription reads \(-3.0\,\mathrm{D}\). Is the wearer nearsighted or farsighted, and what is the lens’s focal length? (b) You swap a telescope’s \(25\,\mathrm{mm}\) eyepiece for a \(10\,\mathrm{mm}\) one. What happens to the magnification? Does the telescope now gather more light?

    Answer

    Answers to Checkpoints

    Checkpoint 32.5. (a) Negative power means a diverging lens, which corrects nearsightedness. Its focal length is \(f = 1/P = 1/(-3.0\,\mathrm{D}) = -0.33\,\mathrm{m}\), or \(-33\,\mathrm{cm}\). (b) Since \(M = -f_o/f_e\), cutting \(f_e\) from \(25\) to \(10\,\mathrm{mm}\) raises the magnification by a factor of \(2.5\). The light gathered does not change: it is set by the area of the objective, not by the eyepiece. The image is larger but no brighter, and in fact the same light is spread over a larger apparent area.


    This page titled 32.5: Optical Instruments was last modified on Thu, 12 Nov 2026 04:27:15 GMT and is shared under a CC BY 4.0 license and was authored, remixed, and/or curated by Michael Ragsdale.