Chapter 20 showed why electrical power is transmitted at high voltage: for a given power, a higher voltage means a smaller current, and the power lost in the lines, \(I^2R\), falls as the square of the current (Example 20.10). But generators produce tens of kilovolts, not hundreds, and homes use a hundred or two hundred volts, not hundreds of thousands. The device that changes one voltage into another is the transformer. It depends on mutual inductance.
A transformer consists of two coils wound on a common iron core (Figure 25.4). An alternating voltage \(V_p\) is applied to the primary coil, of \(N_p\) turns. The alternating current in it produces an alternating flux in the core, which, because iron has such a large permeability, is confined almost entirely within the core and passes through the secondary coil, of \(N_s\) turns. For an ideal transformer, with no flux leakage and no losses, the flux \(\Phi_B\) through every turn of both coils is the same. By Faraday’s law, the emf induced in each coil is \(N\,d\Phi_B/dt\), and with the same \(d\Phi_B/dt\) for both,
Key Equation: The ideal transformer
\[\frac{V_s}{V_p} = \frac{N_s}{N_p}, \qquad \frac{I_s}{I_p} = \frac{N_p}{N_s}. \tag{25.11}\]
The voltage ratio equals the turns ratio. A transformer with more turns on the secondary than the primary is a step-up transformer; one with fewer is a step-down transformer. The current relation follows from energy conservation: an ideal transformer has no losses, so the power delivered to the secondary circuit equals the power drawn by the primary, \(V_pI_p = V_sI_s\). Stepping the voltage up steps the current down in the same ratio. A transformer does not create energy; it trades voltage for current.
Example 25.7: A phone charger
An old-style phone charger contains a transformer that steps \(120\,\mathrm{V}\) ac down to \(6.0\,\mathrm{V}\). (a) If the primary has 1200 turns, how many does the secondary have? (b) If the phone draws \(1.0\,\mathrm{A}\) from the secondary, what current does the primary draw, assuming an ideal transformer?
Solution
(a) \(N_s = N_p\,(V_s/V_p) = (1200)(6.0/120) = \boxed{60}\) turns.
(b) \(I_p = I_s\,(N_s/N_p) = (1.0)(60/1200) = \boxed{0.050\,\mathrm{A}}\). The power is \(6.0\,\mathrm{W}\) on both sides. (Modern chargers use electronic switching circuits and much smaller, higher-frequency transformers, but the principle is the same.)
Example 25.8: From power station to home
A generator produces power at \(20\,\mathrm{kV}\). A step-up transformer raises this to \(400\,\mathrm{kV}\) for transmission, and near the city a chain of step-down transformers lowers it to \(240\,\mathrm{V}\) for homes. (a) What is the turns ratio of the step-up transformer? (b) By what factor does stepping up the voltage reduce the power lost in the transmission lines, compared with transmitting at \(20\,\mathrm{kV}\)?
Solution
(a) \(N_s/N_p = V_s/V_p = 400/20 = \boxed{20}\).
(b) For the same power, the current in the lines is reduced by the factor \(20\). The loss \(I^2R\) is reduced by \(20^2 = \boxed{400}\). Without transformers, alternating current would have no advantage over direct current, and a national grid would waste most of its power as heat. That is why George Westinghouse’s ac system, using transformers, won out over Thomas Edison’s dc system in the “war of the currents” of the 1880s and 1890s. (Today some very long lines use direct current at high voltage, with electronic converters at each end, but the power still passes through transformers on the way.)
Only for changing currents. A transformer works only if the flux in its core changes. Connect its primary to a battery, and after the brief transient of Section 25.3 the current is steady, the flux is constant, and nothing is induced in the secondary. That is the main reason why electrical power is distributed as alternating current (Chapter 26).
Real transformers. Large transformers are more than \(99\%\) efficient, but not perfectly so. Their losses come from the resistance of the windings; from eddy currents in the core, reduced by building the core from thin insulated sheets of iron (Section 24.2); and from hysteresis in the core as it is magnetized back and forth, reduced by using soft magnetic material (Section 23.7). The energy lost appears as heat, which is why large transformers are cooled by circulating oil, and as the familiar hum, as the core vibrates at twice the frequency of the ac supply.
Checkpoint 25.4
(a) A transformer’s secondary has half as many turns as its primary. Is it a step-up or a step-down transformer? How do the secondary voltage and current compare with the primary’s? (b) Why would connecting a transformer’s primary to a car battery accomplish nothing, except perhaps to overheat the primary coil?
Answers to Checkpoints
Checkpoint 25.4. (a) Step-down. For an ideal transformer, \(V_s/V_p = N_s/N_p = \tfrac{1}{2}\), so the secondary voltage is half the primary’s. Power in equals power out, \(I_pV_p = I_sV_s\), so the secondary current is twice the primary’s. (b) A transformer works by induction, which requires a changing flux. A battery’s steady current makes a steady flux, so after an instant no emf is induced in the secondary: there is no output. Worse, with no changing flux there is no back emf in the primary to limit its current, only the coil’s small resistance, so a large steady current flows and heats the primary.
This page titled 25.4: Transformers was last modified on Thu, 12 Nov 2026 04:27:15 GMT and is shared under a CC BY 4.0 license and was authored, remixed, and/or curated by Michael Ragsdale.