26.6: Power in AC Circuits

Physics: A Foundation for Scientists and Engineers · LibreTexts

0%

Contents

    Text

    Size
    100%
    Theme
    Typeface
    Line length
    Spacing

    Read aloud

    How

    Speed: 1×
    Light up
    Highlight

    Symbols: Mulberry Symbols, © 2018–2026 Steve Lee, CC BY-SA 4.0 (licence, the set), the site's own copies.

    From LibreTexts, under CC BY 4.0, as the source states it; its equations are written in TeX, which the PDF shows typeset. This page at LibreTexts.

    26.6: Power in AC Circuits
    Graphs of voltage, lagging current and instantaneous power against time in an ac circuit.
    Figure 26.7. Instantaneous power in an ac circuit where the current lags the voltage by \(\phi\). The power \(p = vi\) oscillates at twice the source frequency and is briefly negative, as the circuit’s fields return energy to the source. Its average is \(I_{\text{rms}}V_{\text{rms}}\cos\phi\).
    Figure descriptionGraphs against time of the voltage v, a sine curve; the current i, which lags the voltage by a phase angle phi; and the instantaneous power p, their product. The power curve oscillates at twice the frequency; it is mostly positive but dips below zero for part of each half cycle. A horizontal dashed line shows its average value, P average, which is positive but smaller than the peak.

    The instantaneous power delivered by the source is \(p = vi\). For a resistor, \(v\) and \(i\) are in phase, their product is never negative, and the average power is \(I_{\text{rms}}^2R\). For an ideal capacitor or inductor, \(v\) and \(i\) are \(90^\circ\) apart, and their product is positive half the time and negative half the time (Figure 26.7). Energy flows into the element’s field for a quarter cycle and back out to the source the next, and the average power is zero. Capacitors and inductors store and return energy; only resistance dissipates it.

    In a series RLC circuit, then, the average power is the power dissipated in the resistor, \(P_{\text{avg}} = I_{\text{rms}}^2R\). Since \(R = Z\cos\phi\) (Figure 26.5b) and \(I_{\text{rms}}Z = V_{\text{rms}}\), this can be written

    Key Equation: Average power in an ac circuit

    \[P_{\text{avg}} = I_{\text{rms}}^2R = I_{\text{rms}}V_{\text{rms}}\cos\phi. \tag{26.9}\]

    The factor \(\cos\phi\) is the power factor. For a purely resistive circuit, or any circuit at resonance, \(\phi = 0\) and the power factor is 1: the source delivers the full \(I_{\text{rms}}V_{\text{rms}}\). For a circuit that is mainly reactive, \(\cos\phi\) is small, and the source must supply a large current to deliver a modest power.

    Example 26.8: Power in the RLC circuit

    Find the average power delivered to the circuit of Example 26.6, and its power factor.

    Solution

    \(P_{\text{avg}} = I_{\text{rms}}^2R = (0.52)^2(200) = \boxed{54\,\mathrm{W}}\). The power factor is \(\cos\phi = R/Z = 200/230 = \boxed{0.87}\). As a check, \(I_{\text{rms}}V_{\text{rms}}\cos\phi = (0.52)(120)(0.87) = 54\,\mathrm{W}\). At resonance, with \(I_{\text{rms}} = 0.60\,\mathrm{A}\) and a power factor of 1, the power would be \((0.60)(120) = 72\,\mathrm{W}\).

    Example 26.9: Why utilities care about power factor

    An industrial motor uses \(10\,\mathrm{kW}\) from a \(240\,\mathrm{V}\) (rms) supply, with a power factor of \(0.70\) (motors are inductive). (a) What current does it draw? (b) By what factor would the power lost in the supply lines drop if the power factor were raised to 1?

    Solution

    (a) From \(P_{\text{avg}} = I_{\text{rms}}V_{\text{rms}}\cos\phi\),

    \[I_{\text{rms}} = \frac{P_{\text{avg}}}{V_{\text{rms}}\cos\phi} = \frac{10\,000}{(240)(0.70)} = \boxed{60\,\mathrm{A}}.\]

    (b) With a power factor of 1, the current for the same power is \(10\,000/240 = 42\,\mathrm{A}\). The line losses go as \(I^2\), so they drop by the factor \((0.70)^{-2} = \boxed{2.0}\). The extra current at a low power factor does no useful work, but it heats the wires and ties up the capacity of generators and transformers. Utilities therefore charge industrial customers for low power factors, and factories install banks of capacitors beside their motors. The capacitors’ leading current cancels the motors’ lagging current, bringing the power factor close to 1.

    Checkpoint 26.4

    (a) A circuit contains only an ideal inductor and a capacitor. What average power does the source deliver? (b) An appliance is labeled \(1200\,\mathrm{W}\) and \(12\,\mathrm{A}\) at \(120\,\mathrm{V}\). What is its power factor?

    Answer

    Answers to Checkpoints

    Checkpoint 26.4. (a) Zero. In ideal inductors and capacitors the current and voltage are \(90^\circ\) out of phase, so the power factor \(\cos\phi\) is zero: energy flows into the elements for a quarter cycle and back to the source for the next, averaging to nothing. (b) The power factor is the real power divided by \(V_{\rm rms}I_{\rm rms}\): \(\cos\phi = 1200/[(120)(12)] = 1200/1440 \approx 0.83\).


    This page titled 26.6: Power in AC Circuits was last modified on Thu, 12 Nov 2026 04:26:59 GMT and is shared under a CC BY 4.0 license and was authored, remixed, and/or curated by Michael Ragsdale.