Opening the book…
Concentration is the amount of a substance in a stated quantity of mixture. Common expressions include mass per volume, molarity, percent, and a multiple of working strength such as 10× or 100×. Always check what the units mean.
A stock solution contains a component at a concentration used to prepare a more dilute mixture. For a simple dilution in which the amount of that component is conserved, use C₁V₁ = C₂V₂. C₁ is stock concentration, V₁ is stock volume, C₂ is final concentration, and V₂ is final total volume.
Keep concentration units consistent and volume units consistent. The equation does not tell you whether the component is stable, compatible, or appropriate for the cells.
Worked example 1: Prepare 100.0 mL of final medium with 2.0 mM glutamine from a 200 mM stock, assuming the starting medium contains none.
V₁ = (2.0 mM × 100.0 mL) ÷ 200 mM = 1.0 mL stock.
Use 1.0 mL stock and enough of the other components to reach 100.0 mL total. If glutamine is the only addition, that leaves 99.0 mL basal medium. If other supplements are included, subtract their volumes as well.
Worked example 2: Prepare 100.0 mL of final medium containing 10% FBS by volume.
Serum volume = 0.10 × 100.0 mL = 10.0 mL. If serum is the only addition, use 90.0 mL basal medium.
Adding 10.0 mL serum to 100.0 mL basal medium produces 110.0 mL total. The serum fraction is then 10.0 ÷ 110.0 × 100% = 9.09%, not 10%.
Worked example 3: A 100× supplement is needed at 1× in 50.0 mL final medium. Stock volume = 50.0 mL ÷ 100 = 0.50 mL, or 500 µL. The other components together must provide the remaining 49.50 mL.
These examples assume that volumes can be added for the preparation. Follow the formulation's method for establishing final volume, especially when preparing solutions from solids or concentrated products.
This page titled 6.11: Calculating Final Concentrations was last modified on Wed, 21 Oct 2026 01:34:30 GMT and is shared under a CC BY-NC-SA 4.0 license and was authored, remixed, and/or curated by Emalee MacKenzie.
The book could not be loaded just now.