Opening the book…
Laboratory safety begins with identifying hazards and evaluating the risks of the actual procedure. Equipment, practices, and PPE provide complementary protection. Biosafety cabinets, clean benches, and chemical fume hoods have different purposes. Their appearance or a general “hood” label does not establish suitability. Microscopes support observation, while their optical design and settings determine what can be seen. Careful cleaning and documentation preserve useful performance. Pipettes must fit the required volume and be used with suitable technique. Accuracy, precision, and verification are related but distinct ideas. Centrifuge force depends on both speed and rotor radius. Balanced loading, compatible parts, and appropriate containment support safe separation. Incubators and supporting equipment maintain selected conditions. A setpoint or normal appearance alone does not establish readiness. Appropriate pre-use checks and complete records help protect workers, cultures, and the reliability of experimental results. Choose equipment for the material, procedure, and measurement. Then check that it is ready and use it within its intended conditions. Record actual settings, readings, and relevant events. If results are unexpected, review equipment performance alongside possible biological causes. Safe operation and reliable measurements depend on the same careful preparation.
Key Terms
|
Hazard |
risk |
aerosol |
risk assessment |
|
biological hazard |
chemical hazard |
physical hazard |
engineering control |
|
administrative control |
PPE |
biosafety level |
SDS |
|
chemical hygiene plan |
Class II BSC |
laminar flow clean bench |
chemical fume hood |
|
HEPA filtration |
certification |
sash |
grille |
|
inverted microscope |
upright microscope |
magnification |
resolution |
|
brightfield |
phase contrast |
fluorescence |
serological pipette |
|
micropipette |
pipette controller |
air displacement |
forward pipetting |
|
filtered tip |
accuracy |
precision |
calibration |
|
verification |
centrifuge |
rotor |
pellet |
|
supernatant |
rpm |
RCF |
incubator |
|
setpoint |
aspiration system |
pre-use check |
equipment log |
Review Questions
1. Explain how a hazard differs from a risk.
2. Why can the same material require different controls in different procedures?
3. Give an example of an engineering control, an administrative control, and PPE.
4. What information would you seek in an SDS before using an unfamiliar chemical?
5. Compare a Class II BSC, a clean bench, and a chemical fume hood.
6. Why does HEPA filtration not establish protection from hazardous chemical vapors?
7. Explain why blocking a cabinet grille can affect performance.
8. Distinguish magnification from resolution.
9. Why is an inverted microscope useful for many culture vessels?
10. Which pipette would you select for 10 microliters if the available ranges are 2–20 and 20–200 microliters?
11. Give an example of a precise but inaccurate transfer.
12. Why can two rotors produce different RCF values at the same rpm?
13. Calculate RCF for a specified radius of 8 cm at 2,000 rpm.
14. Explain why an incubator setpoint alone does not establish the conditions experienced by a culture.
15. What should be recorded when a required equipment check fails?
Apply Your Understanding
A technician needs to transfer 100 microliters of a cell suspension. The available pipette has an acceptable service status but shows visible leakage during a pre-use check. A second pipette has no visible damage, but its identity and service record cannot be confirmed. The technician is also assigned a centrifuge procedure written in × g, while the centrifuge currently displays rpm.
Explain what must be resolved before work proceeds. Describe the information needed to select a pipette and set the centrifuge correctly. State which observations belong in the equipment record and why copying the expected values would be inadequate.
A stem cell culture doubles in cell number. A student concludes that the cells have successfully self-renewed. Explain why the increased count alone is not enough to support this claim. What evidence would help determine whether the new cells retained their stem cell properties?
Two groups grow the same cells with the same nutrients and growth factors, but they use different attachment surfaces. The cells develop different shapes and growth patterns. Explain how their physical surroundings could contribute to these differences. How would you design a comparison to investigate the effect of the surface?
After a treatment, a culture contains fewer cells than its untreated control. A researcher concludes that the treatment killed the cells. Explain how a change in cell cycle progression could also produce this result. What measurements would help distinguish slower division from increased cell death?
This page titled 2.15: Chapter Summary was last modified on Wed, 21 Oct 2026 01:35:36 GMT and is shared under a CC BY-NC-SA 4.0 license and was authored, remixed, and/or curated by .