1.4.4: Aseptically Transferring Bacteria From Broth Culture to Sterile Agar Slant

OER - BIOL 2420 Laboratory Manual · LibreTexts

0%

Contents

    Text

    Size
    100%
    Theme
    Typeface
    Line length
    Spacing

    Read aloud

    How

    Speed: 1×
    Light up
    Highlight

    Symbols: Mulberry Symbols, © 2018–2026 Steve Lee, CC BY-SA 4.0 (licence, the set), the site's own copies.

    From LibreTexts, under CC BY 4.0, as the source states it; its equations are written in TeX, which the PDF shows typeset. This page at LibreTexts.

    1.4.4: Aseptically Transferring Bacteria From Broth Culture to Sterile Agar Slant
    1. Begin by disinfecting your work area.
    2. Obtain all the necessary items to complete the exercise:
      • Bunsen burner
      • Inoculating loop
      • Sharpie
      • Bacterial stock culture (the identity of the bacteria present in the stock culture will be provided by the instructor during the laboratory session)
      • Sterile agar slant tube
    3. Label the sterile agar slant with the following information using the sharpie:
      • Your initials
      • Your lab section
      • Date
      • Initials of the bacteria provided by your instructor
    4. Light your Bunsen burner. Be sure to adjust the Bunsen burner so that an inner blue cone is clearly visible.
    5. Grasp your inoculating loop in your dominant hand holding it like a pencil. You will use the first three fingers of your dominant hand to manipulate your inoculating tool.
    6. Flame the inoculating loop ensuring that it turns red hot, and then let it cool for approximately 15-30 seconds. Do not allow the instrument to bump against anything and do not lay it down to allow it to cool.
    7. Use your non-dominant hand to pick up the test tube containing the bacterial culture. Flick the test tube to suspend the bacteria in the culture.
    8. Use the last two fingers of your dominant hand to remove the cap of the test tube. Do not set the cap down on the lab bench.
    9. Pass the mouth of the test tube through the flame of the Bunsen burner.
    10. Use the sterilized loop to obtain a loopful of sample, without touching the sides of the test tube.
    11. Hold the loop steady and pass the mouth of the tube through the flame and then recap the test tube. Place the test tube back in the test tube rack.
    12. Pick up the sterile slant agar. Remove the cap using the smallest two fingers of your dominant hand.
    13. Flame the mouth of the test tube.
    14. Insert the loop containing the inoculum and streak the surface of the agar starting at the bottom of the tube moving upward.
    15. Flame the mouth of the tube. Recap the test tube and return it to the test tube rack.
    16. Flame the loop until it is red hot. Flaming the loop kills any bacteria remaining on the instrument.
    17. Place your inoculated agar slant in the incubator in the designated location to incubate for 24 hours. You will examine your agar slant in the next laboratory session.

    This page titled 1.4.4: Aseptically Transferring Bacteria From Broth Culture to Sterile Agar Slant was last modified on Sat, 25 Jul 2026 03:43:10 GMT and is shared under a CC BY 4.0 license and was authored, remixed, and/or curated by Sherry Smith.