General characteristics include appearance, color, clarity, pH, visible particles, and water content where relevant.
Use approved methods and precautions; direct smelling of an unknown material is not a routine instruction for assessing odor.
Identity tests determine whether the material is the intended substance or product. Methods may include chromatography, mass spectrometry, peptide mapping, sequencing, spectroscopy, immunological tests, or nucleic acid methods. Complementary methods can strengthen identification, but there is no universal rule requiring two assays for every material. Confirming identity is different from demonstrating reproducibility.
Purity and impurity tests assess specified unwanted materials. Examples include product-related variants, residual host-cell proteins or DNA, microbial contamination, and process residues. Absence of a detected impurity is a statement about the method and sample, not proof that the material is absolutely pure.
Bacterial endotoxin testing detects endotoxin associated with Gram-negative bacteria. Limulus amebocyte lysate (LAL) methods use a biological reaction from horseshoe crab-derived reagents. Depending on the method, detection may involve gel formation, turbidity, or a color change. Recombinant reagent methods are also available; USP Chapter 86 provides additional techniques using nonanimal-derived reagents. Applicable requirements and method suitability must be assessed. Endotoxin is one type of pyrogen, so an endotoxin test does not detect every possible pyrogen.
Mycoplasma tests may use nucleic acid amplification or other suitable methods. Microbial and viral testing approaches depend on the organism, product, sample, and required claim. A PCR result can indicate target nucleic acid without necessarily demonstrating a viable organism.
Content or concentration tests measure the amount of a specified analyte in raw materials, intermediates, or finished products. Suitable methods can include chromatography, spectrophotometry, or other validated approaches. A total protein measurement does not necessarily distinguish active product from inactive protein or contaminants.
Potency or biological activity tests measure a product’s ability to produce a defined effect relevant to its intended activity. A cell-based bioassay may assess a response to a biological medicine; an enzyme assay may assess conversion of a substrate. Potency is not limited to measuring an effect directly in a patient, and concentration and potency are not interchangeable.
Stability studies evaluate whether a product maintains relevant attributes within specifications over time under defined storage conditions. Measurements can include potency, content, degradation products, physical changes, microbial quality, and container-closure effects. Degradation kinetics may support understanding, but shelf-life conclusions require appropriate evidence for the actual product and conditions.
The dosage form and route of administration help determine which tests are needed. A tablet, an injectable solution, and an ophthalmic product do not necessarily have the same quality requirements.
This page titled 15.1: Categories of Quality Tests was last modified on Mon, 09 Nov 2026 00:03:47 GMT and is shared under a CC BY-SA 4.0 license and was authored, remixed, and/or curated by Emalee MacKenzie.