Incoming resources may include active ingredients, excipients, culture media, gases, containers, closures, and other components. These categories are related but have different functions and testing needs. A vial is a packaging component, not a chemical raw material.
A material specification defines the required identity, characteristics, acceptance criteria, and methods or references used to assess conformity. Compendia and other standards, such as USP–NF, the British Pharmacopoeia, the Food Chemicals Codex, or ACS reagent specifications, may help define requirements. The appropriate grade depends on intended use; appearing in a catalogue with a recognized grade does not by itself qualify a supplier or release a lot.
Materials need an identifier, a clear description, relevant quality criteria, approved methods, suitable packaging, storage conditions, and supplier information. Chemical formula and molecular mass are useful when applicable, but they do not describe every biological material or packaging component.
At receipt, inspect and document the shipment, supplier identity, lot numbers, quantity, condition, and any required temperature or transport information. Maintain links between supplier lot numbers and internal identifiers. Hold materials under defined status controls until the authorized quality unit makes a disposition decision.
For finished pharmaceutical manufacturing, 21 CFR 211.84 requires each lot of components, containers, and closures to be withheld from use until appropriately sampled, tested, or examined and released. Components require at least one identity test, using a specific identity test where one exists. Reliance on a supplier’s analysis for certain other attributes is permitted only when the applicable conditions are met, including establishing the reliability of supplier results at appropriate intervals.
Choose tests based on the material, relevant risks, and required attributes. Methods may include chromatography, spectroscopy, physical tests, or biological assays. It is not a general requirement or necessarily appropriate to test an incoming material using the same method as the finished product. A method must be suitable for the sample and intended decision.
Prevent mislabeling and mix-ups, preserve traceability, maintain suitable storage, and ensure that released status is clear before use. Control hazards, moisture sensitivity, temperature requirements, shelf life, and retest periods where applicable. Investigate damaged containers or other evidence of a possible problem.
Example Material Specification Fields
This is a document-content example. Actual acceptance limits and methods must be defined and approved for the material and intended use.