American Architect and Building News, September 1929
The text was read from the page scans by machine (OCR), so it has mistakes and its columns may run together. See the pages · About this title · At the Internet Archive
Page 1
#AMERICAN ARCHITECT Founded 1876 VOLUME CXXXVI ` SEPTEMBER 1929 NUMBER 2575 ARCHITECTURE IN THE NORTHWEST SHOWS A TRUE MODERN SPIRIT By DWIGHT JAMES BAUM, A.LA. ILLUSTRATIONS АКЕ REPRODUCED FROM THE ORIGINAL NEGATIVES BY THE AUTHOR S the steamer sails up the bay to Seattle, one begins to feel the throb of the Great North- west, a country that has torn itself out of the wilderness by sheer physical vitality; that now numbers among its buildings some of the finest examples of modern architecture built anywhere in the United States; and that on every hand shows vision in planning and sound originality. The Northwest is, of course, largely if not entirely made up of Easterners—at least within the past two generations. Therefore the back- ground of the architects practicing there is inevita- килиш л А WELL DESIGNED ENTRANCE ТО А SUB-DIVISION—BROADMOOR, FOR SEPTEMBER 1929 Yet on this background they have grafted an originality that lends their buildings a distinctive character. Above all, the might be characterized by the term There is none of the labored striving after effect that achieves a startling novelty whose merit bly that of the East. architecture of the Northwest “common sense." is in novelty alone, a novelty that fades in attrac- tiveness and investment value as the years cause a true artistic balance to be struck. Towns are planned with a sweeping vision that builds for an irridescent future as well as for a pro- SEATTLE, WASH. 211
Page 2
gressive present. There аге few, if апу, buildings erected that as time passes will become a blot upon the landscape—something that can not be said of our Eastern cities. When Gary, Ind., for instance, was planned as a model industrial city, an excellent job was done. Yet Longview, Wash., a city of 12,000 people, surpasses it not only in its general planning but in the attention paid to schools, civic buildings and the general development of the town as a whole. Though the town is only some five years old, the fine group of school buildings and the cultivated beauty of its parkways and lakes give a long-settled appearance to this young commu- nity. The library, designed by М. Torbitt, and forming one of the illustrations of this article, is most attractive and is placed in a beautiful setting in the Civic Center. The town itself, which was established by the Long Bell Lumber Company, is laid out on a real city plan about a beautiful boulevard with the Civic Center at one end and the railroad station at the other. Incidentally, it is an excellent illustration of what can be accomplished by adhering to a well thought out plan. Though the planning and work was done just as quickly HOUSE OF MRS. GUY L. WALLACE 212 PORTLAND, ORE as that at Gary, Longview is far ahead of Gary. This seems to be typical of the Northwest, for the people appear to be so full of optimism that their accomplishments are completed in a shorter time than that taken by the Easterners, in spite of the latter’s background and superior organization. As one enters Seattle, the city seems to radiate a freshness that is most interesting. The visitor feels a sense of awe at the great accomplishments of the past few years, notable not only as human accomplishments, but for their architectural excel- lence. The new Olympic Hotel, designed by George B. Post and Sons, architects of New York, presents one of the finest hotel structures, inside and out, to be seen in this country. The new shops in Seattle have real distinction The Woman's Shop of Mangin, in the Fifth Ave- nue Building, is one of the finest in any commu- nity and has a true metropolitan air. The ten-acre tract owned by the University of Washington in the center of the city has been de- veloped into a smart shop, office and theatrical district, with the simple, new white Skinner Build- ing and the Olympic Hotel as the center. Many line the downtown other buildings important -А. GLENN STANTON, ARCHITECT THE AMERICAN ARCHITECT
Page 3
THE NEW POLICY OF THE AMERICAN ARCHITECT RCHITECTURE is as old as human habitation. It has housed mankind and his activities since the first man crawled beneath the shelter of his crude hut, and it has always led the way in the march of civilization, reflecting the changing moods of peoples, making better and more pleasing the handiwork of those who build and leaving its stamp on the pages of the world’s history. § High ideals have always been a part of true architecture. Beauty has ever been an aim. Skill has combined. attractiveness with the utilitarianism of every day. The architect himself has always been and ever will be an idealist, a seeker of better things, a worshipper of beauty, a lover of the fine, the true. Yet with it all he has today stepped into the front ranks of the world’s business men—a combination of characteristics not found elsewhere in modern civilization. § Worshipper of beauty that he is, he is invariably drawn to excellence in design. The work of other men has an attraction for him. He must ever be a student of what others do that he may do better himself. Based upon this premise the field of architecture has developed a group of publications that for execution and contents are not equalled in any other magazine group in any field. § But times change. Architecture has ever been in process of change. And the architect himself today is changing more rapidly than in any other period in the history of architecture. Today the office of many architects is less a studio than a business institution. The work of design has had to be combined with that of management, finance and business method. The architect of today is not the same man he was when The American Architect was founded over a half century ago. $ Recognizing this enlarged character of architecture, The American Architect will henceforth endeavor to present a picture broader than has been its custom heretofore. 4 Foremost in architecture is design, and that phase of the publication’s work will never be dropped, but careful selection will be made of those designs that are presented and explanation will be made of the reasons for their presentation. All these old traditional characteristics of the magazine will be retained and improved. Criticism of design will not be uncommon. § The architect, beyond design, has many problems, his relations with his clients, the building of his work into a bigger business, his relations with the erectors of the buildings he plans, the internal operation of his business at lowest cost and best results, the securing of and relations with employees, and countless other detail problems of the everyday world. 4 All these things in ever broadening scope will become a part of the new American Architect. It will endeavor to paint a current picture of this profession and business with such interest and value that no matter what a man may do, be he proprietor or employee, if that man is a part of architecture he will want to read this magazine.
Page 4
REPRODUCTION ОЕ THE ANCIENT САТ ОЕ BUBASTIS ONE OF À AT THE ENTRANCE TO СО FACTORY, LONDON THE AMERICAN АКСНІТЕСТ September 1929
Page 5
FOR SEPTEMBER 1929 HOUSE ІМ BROADMOOR, SEATTLE, WASH ARTHUR LOVELESS, ARCHITECT HOUSE IN MOUNT BAKER SECTION, SEATTLE, WASH.
Page 6
THE UNITARIAN CHURCH ОЕ OUR FATHER АТ PORTLAND, ORE., DESIGNED BY JAMIESON PARKE IS AN E MPLE OF A WELL DE- TAILED BUILDING BASED UPON EARLY AMERI- CAN PRECEDENT THE MOUNT BAKER SECTION OF SEATTL WASH., CONTAINS MANY FINE RESIDENCE THE HOUSE SHOWN BELOW IS A PARTICULAR GOOD EXAMPLE OF THE PICTURESQUE YET SIMPLE AND DIGNIFIED TYPES TO BE FOUND IN THIS DEVELOPMENT 5% THE AMERICAN ARCHITECT
Page 7
ІМ THE HOUSE HEIGHTS, A. E. MATERIALS MAKES TERIAI THE HOUSE SHOWN BELOW IS AN EXAMPLE OF WOOD LARLY INTERESTING AND APPROPRIATE DISTRICT WHERE LUMBER IS A GREAT IND! TRY. HAROLD W z FOR THIS HOUSE A TREATMENT FOR SEPTEMBER IN OF J. DOYLE AND USED TE N А HOUSE IT AND PROPOR DOTY WAS THE WHICH IS AT PORTLAND. 1929 5 SELECTED 1 TO GOOD ADVAN
Page 8
streets, buildings that would be noticed anywhere. The recently completed Northern Life Tower, which is of purely modern architecture in which vertical lines are accented, is done in far more suc- cessful manner than some New York office build ings contemporaneous with it. The University campus is beginning to take on a character all its own, partly through the new buildings designed by Bebb and Gould. The library, although only partly completed at the time of the writer's visit, shows both distinction and а restraint that is refreshing. The new suburb “Broadmoor,” as well as the Mount Baker district, have many attractive homes. Unfortunately, the writer was not able to photo- graph many buildings in Tacoma. In Point De- fiance Park is a well studied Tudor residence of importance. The National Bank of Tacoma, the First Presbyterian Church, a brick building in the Romanesque style with good detail, the Scottish Rite Cathedral of conservative modernism, and the Wright Seminary for Women in brick Tudor style are all notable buildings. Motoring down the famous Columbia River highway to Portland, one is somewhat prepared by its beauty to expect a fine residential city— and there is no disappointment Much of the architecture here is of a so-called modern type which would be criticised by many modernists, though to the writers mind it expresses a true, modern conception. Though its forms are based on the past, its handling is done in a new manner which reveals a soundly conservative originality that is thoroughly impressive because of its com- mon ‘sense handling of the problems involved. Perhaps the word "rational" expresses its character as well as any word can. In the commercial section, besides the buildings illustrated, the Bank of California and the Security Savings and Trust Company are buildings of merit. At the University of Oregan, Lawrence and Holford have done several interesting build- ings, while their little church at Tillomook has a The Floyd Frank resi- dence, by Herman Brookman, is, the writer be- lieves, one of the most interesting houses in the Northwest. While in pleasure of attending a meeting and dinner in Seat- tle of the Washington Chapter and, in Portland, of the Oregon Chapter of the American Institute of Architects. The number present, their interest and enthusiasm, showed that the architectural future of our great Northwest is in good hands. quaint charm all its own. the Northwest, the writer had the “шшш PCK RPA ARCHITECTURE OF SPANISH INSPIRATION IS APPROPRIATE TO THE NATURAL SURROUNDINGS AND CLIMATIC CONDITIONS OF BEVERLY HILLS 216 CALIF. THE AMERICAN ARCHITECT
Page 9
HOUSE АТ BEVERLY HILLS, CALIF. FROM А PHOTOGRAPH BY DWIGHT JAMES BAUM FOR SEPTEMBER 1929 n ч
Page 10
MILTON В. MEDARY, FALA. 1874—1929 М THE death of Milton B. Medary, the pro- fession has had removed from its ranks a member who was internationally well known, be- loved by all who knew him, a man who had ac- complished much good in the advancement of architecture in the United States. Mr. Medary, a member of the firm of Zantzinger, Borie and Medary, of Philadelphia, Pa., died of heart disease at his home in Bala, Pa., on August 7th. 1929. Milton B. Med- ary was born in Philadelphia on February 6th, 1874, the son of Milton Bennett Medary and Mary Emma Cregar Medary. At the age of sixteen he began the study of architecture at the University of Penn- sylvania. А few years after leaving the University he joined the firm of Field and Medary. In 1905 the part- was and dis- Mr. nership solved Medary continued to practice alone. The firm of Zant- zinger, Borie and Medary was formed in 1910. In 1899 Mr. Medary became an associate mem- ber of the Ameri- can Institute of Architects. The Institute conferred upon him the degree of Fellow in 1910 and awarded him the Gold Medal of the Institute in 1928. Не served as President of the Institute from 1926 to 1928. body. Mr. Medary was always active and keenly in- terested in public affairs and especially those af- In 1927 he became a life member of this fecting the development of good architecture in this country. In 1918 he served as chairman of the Housing Corporation of the Department of Labor to design workmen's villages at Neville 218 Island, Pittsburgh and Bethlehem, Pa. Іп 1922 President Harding appointed him a member of the National Commission of Fine Arts. Presi- dent Coolidge appointed him a member of the National Capital Park and Planning Commission іп 1926. Secretary Mellon named him for a seat on the Board of Architectural Consultants of the Treasury Department in 1927. Іп this same the University of Pennsylvania conferred upon him the de gree of Doctor of Fine Arts, and the Art Club of Phila- delphia awarded him the Gold Medal of this insti- tution. Among tbe many positions held by Mr. Medary were those of consulting architect to Cornell University; director of the Foundation for Architecture and Landscape Architec- ture of Lake Forest, Ш.; President of the Philadelphia Chapter of the A. I. A., T-Square Club, and the Architectural Alumni of the Uni- versity of Pennsyl- honorary year vania; corresponding mem- ber of the Royal Institute of British member of the Architects. Architects; and honorary American Society of Landscape Mr. Medary was a member of many architectural societies; the Philadelphia Zoólogical Society; the Art, Philobibion, Wilderness, Rittenhouse Clubs of Philadelphia, Century Club of New York and the Cosmos Club of Washington. Among the structures of which he or his firm were the designers are the Bok Carillon, or Sing- ing Tower, at Mountain Lake, Fla., the Valley Forge Chapel, the Penn Athletic Club, and Fidelity-Mutual Life Building in Philadelphia. THE AMERICAN ARCHITECT
Page 11
GUARANTY BUILDING AND LOAN ASSOCIATION LOS ANGELES, CALIF. Feil & Paradise, Architects FOR SEPTEMBER 1929 219
Page 12
SLOALIHOWY ‘ASIGVUYd я TI4— PIVO "S ヨ THDNV SOT ‘NOLLVIOOSSY NVOT ANY ONIAIINA ALNVAVA $ ной Ка 504944 М АЕСНІТЕСТ ° m = = で ш ЕЧ Ë
Page 13
SLOdLIHOHY ‘ASIGVUYd 8 sopnig 14 ^ " PW 1929 FOR SEPTEMBER
Page 14
Photos by Mott Studios GUARANTY BUILDING AND LOAN ASSOCIATION, LOS ANGELES, CALIF 2 E, ARCHITECTS THE AMERICAN ARCHITECT
Page 15
DUFWIN THEATRE, OAKLAND, CALIF. Weeks & Day, Architects ТЕ recent developments and changes іп the world of architecture and decorative art, with varied reactions, all of them finally submerged in a growing faith in the future, lead to the modern architectural treatment of the new Dufwin Theatre. Due to the small size of the property and in order to obtain the required number of seats, the rear of the balcony necessarily extended to the street, which produced a solid main facade wall, presenting a difficult exterior surface to design. It was decided to use a modern form of Greek art and architecture, with a certain amount of color and luster to obtain an interesting effect of theatrical character. Since there was no opportunity for openings on the exterior facade, three large color- ful tile panels were designed to obtain а note of interest and color, needed to relieve the severity of the plain wall. “The frames of all three panels are rich in color, of Greek origin and similar in design, with a group of figures in each representing Tragedy, Music and Drama. The upper part is in green, red, blue and gold, with the figures silhouetted against a deep blue background. The pedestals supporting them sparkle with colors of vermillion, umber, yellow and gold, and accents of black. The wall surfaces surrounding the FOR SEPTEMBER 1929 panels are executed in a soft tone of amber pink. Under the group of panels the marquise, severe in treatment, was designed as a part of the exterior composition and structure. The vestibule has a Pompeian vaulted ceiling, decorated with free ornament of brown, green, gold and black, laid carefully over a rich red back- ground. The walls are light Caen stone, relieved with marble trimmed openings. Upon entering the auditorium, the impression is one of simplicity in design, with the same Greek influence as that of the exterior. A wood wainscot encircles the lower part of the auditorium, blend- ing with the soft mellow tones of the walls and ceiling. The proscenium opening is dignified in character, with two gold figures in relief, at the sides near the top, against a glazed blue back- ground. The corners adjacent to the proscenium are treated with pilasters, enclosing recessed mirror panels, over the top of which are decorative panels of figures in gold, on a background of dull blue. The draperies and furniture are warm in color tone. The proscenium is draped in soft crimson and trimmed with gold, which picks up the warm soft tones of the lighting fixtures. The theatre has a seating capacity of 1206. 223
Page 16
“| 8 = 2 — © O Е З = m = а о x < а © の x z | | = | = < U a д < | z < ^ ° x Е < ш š ? Б а {ESTRA FLOOR 224 THE AMERICAN ARCHITECT
Page 17
m РРА | = وس — £= TUR ター У OF EFL PAT OF еден Orit WIŁANCE DETAILS OF FRONT ELEVATION DUFWIN THEATRE, OAKLAND, CALIF. WEEKS % DAY, ARCHITECTS eee FOR SEPTEMBER 1929 225
Page 18
DUFWIN THEATRE, OAKLAND, CALIF. WEEKS 8 DAY, ARCHITECTS 226 THE AMERICAN ARCHITECT
Page 19
の [4] o E E" WEEKS 8 DAY, ARC SUTT RTTE A > с тё / КАЛП EY ЛЛ... ҮСӘР ГС» ТА ur a E - BE 2 а = B [:4 o E 8 5 - FOR SEPTEMBER 1929
Page 20
THE AMERICAN ARCHITECT SAN FRANCISCO, CALIF рое RAPH BY ARMAND CARROLL FERRY BUILDING, FROM A LITHOC N N
Page 21
FOR SEPTEMBER 1929 FIRST PRESBYTERIAN CHURCH, PHOENIX, ARIZ. NORMAN F. MARSH % CO., ARCHITECTS к N や
Page 22
FIRST PRESBYTERIAN CHURCH, PHOENIX, ARIZ NORMAN F. MARSH % COMPANY, ARCHITECTS THE AMERICAN ARCHITECT
Page 23
FIRST PRESBYTERIAN CHURCH, PHOENIX, ARIZ. NORMAN F. MARSH % COMPANY, ARCHITECTS FOR SEPTEMBER 1929 231
Page 24
FIRST PRESBYTERIAN CHURCH, PHOENIX, ARIZ. NORMAN F. MARSH 8 COMPANY, ARCHITECTS THE AMERICAN ARCHITECT
Page 25
INCOME SECURITIES BUILDING, OAKLAND, CALIF. FRED H. REIMERS, Architect Sculptural Decoration Designed by Jobn Stoll Т HE design of the Income Securities Building, at Oakland, California, is unique due to the fact, no doubt, that the structure is largely sculp- tural in conception. It is a six-story building, covering a lot fifty by one hundred feet. While an effort was made to create a design of simple, dignified proportions, void of the monotonous embellishments of orthodox ornament purchased by the yard, the design features certain decorative motives which give it peculiar interest. The facade is buttressed at four points. These buttresses, triangular in shape, terminate in a boldly outlined sculptural eagle. The slope at the terminal of the buttress corresponds with the slope of the parapet wall. The pinions of the eagle fall or continue into the flanking flutings of the but- tresses. The two entrance doors and window be- tween are set in deep splayed reveals. The eagles form a simple, powerful and interpretative finish. Other lines carry the eye to the main motif of the low relief panels above the doors. These are cut to conform with the spirit of the conception as a FOR SEPTEMBER 1929 whole. Repeating the feeling of the slope of the parapet wall, the heads of the figures are cut V-shaped and approximately two inches deep, tapering to a half inch or less toward the feet. The anatomy of the figures is big and powerful. The accentuation of decoration on the building has a logical appeal to mind and eye at the points at which it appears. The panel illustrated above is symbolical of commerce and shipping. Two powerful figures seated on the hawser are envisioning commerce car- riers of the future. Other figures are interpretative of united coóperation and aim. The rope they carry is symbolical of unbroken bond. The eagle and Indian figureheads express the thought of dominion and nationality. One panel illustrated on the following page symbolizes general activities. It is purposeful in spirit and action, and interprets justice in deal- ings, youth and confidence and aspiration. The other panel is a symbolical representation of architecture and the progressive spirit of the art. 233
Page 26
SCULPTURED PANELS, INCOME SECURITIES BUILDING, OAKLAND, CALIF. DESIGNED BY JOHN STOLL THE AMERICAN ARCHITECT
Page 27
REPAIRING РТ СТОР LI Photo by Cohen Co. INCOME SECURITIES BUILDING, OAKLAND. CALIF. FRED REIMERS, ARCHITECT; FACADE DESIGNED BY JOHN STOLI FOR SEPTEMBER 1929
Page 28
HOOTAH ANINVZZAW ному SHHMWIHH ‘н аччя ур GNYTAVO ‘ONIGTING чоопч GNODAS SHLLIHOOSS HINOONI NOOTI 1514 ARCHITECT THE AMERICAN 236
Page 29
LAS ENCINAS SANITARIUM, PASADENA, CALIF. Clarence L. Jay, Architect FOR SEPTEMBER 1929 237
Page 30
WYMAGA LLL LĄ LAS ENCINAS SANITARIUM, PASADENA, CALIF. CLARENCE L. JAY, ARCHITECT 238 THE AMERICAN ARCHITECT
Page 31
FOR SEPTEMBER 1929 LAS ENCINAS SANITARIUM, PASADENA, CALIF. CLARENCE L. JAY, ARCHITECT 239
Page 32
"uni qs 521 NS Yn , ARCHITECT m о a m m < = | d < о < 2 m Q < の < ` - z LAS ENCINAS SANITARI — st = THE AMERICAN ARCHITECT
Page 33
INTERIOR ARCHITECTURE NOTES ON STAINED GLASS AND THE ART OF CLEMENT НЕАТОМ By C. HOWARD E AENT HEATON, in his windows in the ^ Church of the Blessed Sacrament, іп New suited for churches which have not the rich and deep shadows of mediaeval cathedrals, and which therefore do not harmonize with the type of windows used in of stained glass windows bes Chartres Cathedral. The mediaevalists of the later XIIth century desired to introduce light and to give lightness and delicacy to the building, so they intentionally introduced parts in grisaille, designed and executed with great care by the same masters who dealt with the figure and full color windows, yet enough colored glass was introduced to give an appreciable color effect. "They were considered in both French and English cathedrals as an integral part of the architecture. Mr. Heaton WALKER, F.A.LA. has reinstituted this modus operandi in use in the 13th century, but since largely neglected, in the Church of the Blessed Sacrament. The clerestory windows each have, on a field of grisaille, two figures on colored grounds, under canopies. Rich borders surround each opening, so the series of windows forms a vast field of color which decor ates the entire church. The effect of brilliancy is also partly due to the technique adopted. Ancient glass is not more brilliant than it is harmonious in general tone; this is due somewhat to decay of the glass surfaces. То obtain this harmony requires artistic knowledge and skill in the use of painting and patinas. Interest from variety of design accompanies tbe general harmony of tone and color, but there is no haphazard as- semblage of unrelated units. Іп the present case PORTION OF THE ORIGINAL COLOR STUDY BY CLEMENT FOR SEPTEMBER 1929 HEATON FOR THE GREAT ROSE WINDOW. BLUE, RUBY AND WHITE PREDOMINATE WITH SECONDARY COLORS OF YELLOW, GREEN, PURPLE AND LIGHT BLUE CHURCH OF THE BLESSED SACRAMENT, NEW YORK CITY—GUSTAVE STEINBACK, ARCHITECT
Page 34
ORIGINAL 5КЕТСН ІМ REPRODUCTION FROM А PHOTOGRAPH OF AN ACTUAL WINDOW ON PAGE 243 CHURCH OF THE BLESSED SACRAMENT, NEW YORK CITY—GUSTAVE STEINBACK, ARCHITECT COLOR OF CLERESTORY WINDOW BY CLEMENT HEATON. COMPARE WITH THE 242 THE AMERICAN ARCHITECT
Page 35
А Ri 3 i зола) & THE GRISAILLE BACKGROUND ОЕ THE CLERESTORY WIN IMPRESSION OF RICH COLOR ON À TRANSLUCENT WHITE BACKGROUND CHURCH OF THE BLESSED SACRAMENT, NEW YORK CITY—GUSTAVE STEINBACK, ARCHITECT FOR SEPTEMBER 1929 243
Page 36
THE ROSE CHURCH ОР WINDOW, THIRTY-SIX FEET IN THE BLESSED SACRAMENT the whole vista constitutes a color symphony in design in which the score of figures provide his- torical material for study and receive close attention to detail. These figures are the twelve apostles, Saints Thomas Aquinas, Clara, Barbara, Bona- Realistic representation has been so popular that the deep lying principles on which ancient stained glass depends for its beauty ventura and others, 244 DIAMETER, IS ONE OF NEW YORK CITY THE LARGEST GUSTAVE IN THE UNITED STATES STEINBACK, ARCHITECT have not generally been perceived. Stained glass is preéminently design, not literal pictorial repre- sentation, and if it is to some extent an artificial expression, it is therefore the more consistent and harmonious, and architectonic with the architecture it embellishes, exemplifying a practical application of aesthetic principles. The glory of ecclesiastical shrines is the lineal THE AMERICAN ARCHITECT
Page 37
FIVE СІ.ЕКЕ CHURCH OF THE BLESSED SACRAMENT descendant of the mosaics of St. Sophia, St. Marks and the apses and naves of Ravenna. It brings to its aid a penetration of light, not the reflection of it, and becomes a rich design of jewels through which the light passes. It is therefore color decor- ation pitched in the highest possible key; but it requires the added quality of tone or it overwhelms its environment. The early French glass of Le FOR SEPTEMBER 1929 STORY WINDOWS ON EACH SIDE OF NEW YORK CITY a. SS a er „Bo — Aske. көк х= a а: ії «и ME THE NAVE F ТА "WALL OF GLASS" GUSTAVE STEINBACK ARCHITECT Mans and Chartres, enshrined amidst the deep shadows of cathedrals, which depended more upon the candles upon the altars for their illumination than they did upon the light of the day, was rich in intense blues and rubies and greens, glowing bigh under the vaulting as supreme color decora- tion. The drawing of the leading was extremely simple, and what painting there was upon the 245
Page 38
glass to indicate feature and other detail was elemental and strong, so that it would hold its own with the intense color. As the years went by, more light through the windows was found necessary and the 14th century work is characterized by the introduction of more white glass fields with dec- orative patterns. Especially was this the case in England, where this style of stained glass came from France. The English glass became sil- very in charac- ter, which had white fields with glowing color in their midst and around their borders. The use of back- ground texture patterns increas- ed, and the so- called grisaille, made as delicate lace, became admirable foil for the fig- ures, as did the elaborate archi- tectural pies; rich color was maintained on the borders and in the fig- ures. In addi- tion to the painting, which was delineative drawing in black as an cano- or brown, a delicate yellow THE AISLE WINDOWS ARE МОТ I stain appeared. PRACTICALLY THE ONLY ONE Whether the ROUNDING BUII gray of the Eng- lish climate in- duced lighter windows in tone or if they were felt to be in har- mony with the architecture, or both, is merely speculative analysis. At all events, England is famous for her silver windows—York comes to mind—which were also well adapted to the Great Halls of the universities, and of the Inns of Court. Glass, however, at all periods remained thor- oughly architectonic, as were mosaics and mediae- val sculpture, as in the porches of Chartres; and, GUSTAVE 246 DINGS IS SHOWN ABOVE CHURCH OF THE BLESSED SACRAMENT, NEW YORK CITY STEINBACK as the mediaeval framework of structural forms was narrow and vertical, the figures partook of that character. The grouped traceried windows, forced by wind pressure to be narrow, especially de- manded this type, and when these traceries ac- commodated themselves to the arches at the top they created geometric openings, subject to geo- Stained glass was also the expo- nent of religious history. It de- picted the lives of Christ and of Mary the Mother, of the Prophets, the Saints, and the heads of the Church hier- archy, of whom severity, nobil- ity, and power the at- tributes. These attributes were expressed by symbolism, with dignity, creating a classi- cal convention- alism devoid of agitation and of eccentrictiy. It is interesting to note that the great periods of Greek sculpture, of Byzantine mosaics, of early Italian painting and of Japanese prints acknowl- edged the same characteristics in design. The work of Clement Heaton shows his thorough knowledge of glass power, purpose and limitations. Having lived and worked at glass and mosaics in Central Europe, he is thor- oughly conversant with the continental glass, as with the English type which he studied in earlier days. He consequently has a rich choice of types which he uses according to the needs of each building. He especially appreciates the value of the drawing of the leading, a design in itself, which metric patterns. were BY SUR- ARCHITECT well as THE AMERICAN ARCHITECT
Page 39
LT | I ay X RCHITECT m S & ыы о 5 4 > = ж [:4 ғ Ë ғ = > ж се о SZR Eg | GA VERD CS CD Gun Ge tam GER WE 72 PS SR ey VT TT = š ` Y. қ 7 a EO 2 si 2 ws А тіс a = są -— ыы з r > a = EL Жа та E i p» А e "E. : ча 3 = 22” «ТЭР 2 RA MT y= © (zd ~ РА ‘pa? >» == қартая “аф. - == à - = Ф : ^m FOR SEPTEMBER 1929
Page 40
һе keeps іп admirable scale. In the windows of that harmonize tapestry drawings of the 16th the Church of the Blessed Sacrament, the tracery century. The ornamental windows without fig- openings required skilful treatment in the design, ures, which so frequently appear mannered, have especially in the opening of the rose windows. а rich variation of texture, and the distribution of The architectural details of canopies, cusps, crock- color is excellent. This type of work is in ac- ets, and capitals are executed with knowledge, and cordance with the architecture of which it is a part, the borders which surround the lights are interest- richly decorating it but not overwhelming it, and ing and varied, as are the diaper patterns in the embodies not only the traditions but the beauty field. The draperies of the saints, simply painted, of many of the admired stained glass windows have the firm parallelism and radiation of folds of the best period of the glass art of the past. As Era LL. B E == mm | | ZA ЖА š [4 33 < На に — Light < 53 « зі де Fn Shoat < paren LK w 5 LO e PLAN SHOWING GRADATION OF COLOR IN WINDOWS TO SECURE GRADATION OF DAYLIGHT = ж à PANEL OF EACH OF FIVE CLERESTORY WINDOWS SHOWING IN BLACK THE AMOUNT OF COLOR USED IN THE GRISAILLE AS WELL AS THE DESIGN CHURCH OF THE BLESSED SACRAMENT, NEW YORK CITY GUSTAVE STEINBACK, ARCHITECT 248 THE AMERICAN ARCHITECT
Page 41
% ENGINEERING AND CONSTRUCTION + TECHNICAL CONSIDERATIONS IN THE PLANNING OF HOSPITAL X-RAY DEPARTMENTS Ву С. В. BRAESTRUP, B.Sc., A.LE.E. CONSULTING X-RAY ENGINEER, PHYSICIST AT MT. SINAI AND BELLEVUE HOSPITALS, NEW YORK CITY IX the design of a modern hospital probably no other division reguires as much special knowl- edge as that of the X-ray department for in addi- tion to the usual hospital reguirements numerous problems of a technical nature must also be con- sidered. Among these are the protection against penetrating radiation and high tension currents; the accommodation of eguipment which is still in the development stage; the vital guestion of film storage; electrical power reguirements; and the arrangement of the auxiliary circuits to which the usual rules governing ordi- nary electrical equip- ment cannot be ap- TABLE 1: plied. Hospital Location While certain gen- m York ichigan eral rules, together Florida New York New York New York with a few funda- mental physical laws which are necessary in the designing of a safe and efficient roentgenological department, may be stated, it should be borne in mind that every X-ray department presents individual problems re- quiring the fullest coóperation of the architect, ro- entgenologist and hospital authorities. Тһе neces- sary technical and physical advice should be obtain- ed from a physicist or electrical engineer experienced in this field, rather than from haphazard sources. LOCATION AND SPACE REQUIRED In general, the diagnostic and therapeutic appli- cation of X-rays is done under the same super- vision, with the two subdivisions located together and forming the X-ray department. The depart- ment should be centrally located with ready access for hospitalized and out-patients. The rooms must be dry and airy, inasmuch as humidity and heat reduce the insulation of the high tension equipment, causing variation in radiation output or even complete breakdown of the generators. ` FOR SEPTEMBER 1929 RELATION BETWEEN BED CAPACITY AND FLOOR SPACE OF X-RAY DEPARTMENT OF VARIOUS AMERICAN HOSPITALS The practice of placing the X-ray department in basements and often on top of or close to the boiler room is so objectionable that it is hard to believe that this arrangement can still be found in modern hospitals. То insure ample distance from the floor to the overhead high tension con- ductors, the ceiling height should be at least 11 feet with a clearance to beams and pipes of not less than 10 feet. Outside walls are desirable not only for the air and light they afford, but also because they do not require ray proof cov- ering. Similarly, a one-story building used exclusively for radiological purposes means a great saving in protective materials and offers, in addi- tion, a degree of safety to the rest of the hos- pital. However, with proper ray proofing and the use of the so-called safety films any loca- tion meeting the above mentioned requirements should be satisfactory. Table No. 1 indicates the relation between bed capacity and space occupied by the X-ray department for several hospitals. It will be noted that the variation in this ratio is surprisingly small, considering that factors such as the number of out-patients, and amount of teach- ing and research all have a bearing on this rela- tionship of bed capacity, to X-ray department area. As a preliminary estimate, the X-ray department, including halls, may be considered to require 10 square feet per bed. Teaching institutions gen- erally require somewhat more, while general hos- pitals probably can get along with a little less. X-Ray Ratio Floor Space Sq. Ft. Bed Sq. Ft. Capacity 1660 9. 3200 10. 1000 š 7200 11. 4000 1150 Beds 175 302 125 650 420 129 5 ARRANGEMENT OF THE RADIOGRAPHIC ROOMS A survey of X-ray departments shows but little uniformity as to the layout of the rooms in rela- 249
Page 42
tion to each other. The explanation for this is perhaps that roentgenology is still young and de- veloping too rapidly to allow standardization. Likewise, the arrangements of many of the older departments were arrived at by fitting, as far as possible, the radiological needs to the space avail- able. The results thus arrived at were often far from ideal and cannot well be used as a guide for future X-ray departments. The accompanying plan of a typical X-ray department of a 500 to 600-bed hospital illustrates a good arrangement of the various radiological rooms. The usual oblong hospital wing has been assumed rather than a square area, although the latter may adapt itself better to the needs of the X-ray department. While this plan incorporates some of the best features of several recently completed radiological divisions, it indicates, of course, but one solution to the problem. As illustrated, the waiting-room should be near the entrance of the department and close to the office and reception desk. From there the patients are directed to the various dressing rooms. An ample number of these rooms, provided with direct access to corridor and X-ray rooms, will materially increase the number of patients that can be handled. The dressing rooms in connec- tion with the fluoroscopic rooms may also be used as light locks enabling the patients and doctors to enter without disturbing the accommodation of the examining radiologist's eyes. This requires that the dressing room partitions, usually only 7 to 8 feet high, extend to the ceiling and that the dressing rooms be illuminated by colored lights or white lights shut off automatically when the door to the fluoroscopic room is opened. The fluoro- scopic room connects directly with a toilet, barium preparation sink, and a radiographic room. To exclude light during fluoroscopic examinations, the windows are provided with light proof shutters of a type that can easily be opened and closed. Sliding or folding shutters are used in preference to rolling shades. The doors must be light proof because even a small amount of light interferes with good fluoroscopy. Ordinarily a special room is not needed for the fluoroscopic generator. It requires but little space, about 2 feet by 3 feet by 5 feet, and can be placed on a false ceiling above a dressing room or closet. The dark room is logically located between the two main radiographic rooms and opposite the viewing room where the finished films are exam- ined. Various methods are used in entering the dark room without admitting light. The maze, the revolving door or the light lock are the most common. Where sufficient space is available the maze allows passage with the least amount of 250 effort, but may require a door in addition to ac- commodate the moving of large objects. The re- volving door requires the minimum amount of space. The light lock with its two doors is only fool-proof when controlled electrically or me- chanically. Pass boxes are provided for passing the loaded films between dark room and X-ray rooms and hall. Usually there are two together, one for the unexposed and one for the exposed films. Each of these boxes, like the light lock, has two doors of which only one can be open at a time, thus preventing light from entering the dark room. This room is divided into two sections, one for loading and unloading films, and one for developing, fixing, washing and drying the films. A modified arrangement of the dark room is shown in the accompanying plan. In this plan each of the main radiographic rooms has its own loading cubicle. With this arrangement the cassettes with their sensitive intensifying screens are kept out of the dark room and the possibility of moisture damaging the screens is consequently much smaller. This lay-out is particularly well adapted to a very busy hospital where the develop- ment alone is usually enough to keep one man busy all day. It is highly desirable to have a window in the dark room and preferably in the section used for the developing. Light proof shut- ters should be provided as in the fluoroscopic room. Most hospitals use forced pre-heated air for dry- ing the films. Some institutions have even gone a step further, using air from which the moisture has been removed by refrigeration before heating. In this way the drying of the films requires mini- mum time even on very humid days. As the ex- haust air from the dryer is highly humid due to the moisture from the films, it is desirable to have it pass directly to the outside. A vent with auto- matic louvers is therefore provided to fit the dryer selected. In developing the films it is desirable to have the solution at a constant temperature (65 degrees Fahrenheit). This may be accomplished by ther- mostatic control of the circulating water for the purpose of which hot or cold water connections are provided. Depending on the temperature of the cold water, it may be necessary, in the summer time, to cool it by means of a special refrigerator. The location of the two main radiographic rooms between the dressing rooms and dark room permits efficient handling of patients as well as of the films. The control booth is situated so that the operator has ample vision of patient, tube and high tension generator, and at the same time may save himself unnecessary steps. The generators placed above the closets in the dark room, of THE AMERICAN ARCHITECT
Page 43
course, means а saving іп space, but necessitates a fairly high ceiling as most radiographic genera- tors require a height including clearance of 5 to 7 feet. Under any circumstances it is advisable to have separate rooms for the high tension generators as a safeguard against electrical shocks. The cystoscopic and fracture room is located at a greater distance from the dark room because the amount of radiography done here is limited and the handling of films is therefore of less im- portance. The viewing room is opposite the dark room and next to the director's office and near the gen- eral office where the reports on the films are typed. Space is provided in the hall for stretcher cases awaiting attention. ARRANGEMENT OF THERAPY ROOMS The length of exposure and the penetrating ALTERNATE PLAN OF DARK ROOM WITH SEPARATE LOADING CUBICLES power of the rays used in therapy render the ques- tion of protection as well as of comfort to the patient and to the operator of great importance. The typical layout shows an arrangement of the therapy rooms suggested by the writer and now being successfully used at several hospitals. It will be noted that the high voltage treatment rooms are corner rooms offering maximum light and ventilation with minimum cost of protection. The location of the controls gives the operators good vision of patient, tube and apparatus. Con- trary to the usual arrangement, the operators here have plenty of air and light. The passage between the dressing rooms allows communication with the rest of the department. Separate machine rooms are provided, thus permitting inspection and repair of one machine without shutting down the other. ELECTRICAL POWER SUPPLY AND WIRING Wherever possible, alternating current should be used in preference to direct current as power FOR SEPTEMBER 1929 ConrRon К. quo LEAD _ Superr THERAPY ет HERAPY ОРЕ Warr гг лв СК DEV TANK A Box DARK Room “ T" õu | Viewwe + 5% || Demonstration ND 12020 тим i Kf e а (6271 FPB і 2 RapioeRAPHY “ 0 | > рим № DIRECTORS Ore | \ 1579-6" i ン hi: Ji |Bariom | Пете OFFICE = ММ У ВИК. ` ` "d WAITING Room Fivoroscopy "М, M [E | —--—INDICATES № ) OF LEAD oR EQUIVALENT ON ENTIRE = Xe J FLOOR AND ТО HIGH ON WALLS ° s 10. 15 гот PLAN OF TYPICAL X-RAY DEPARTMENT FOR 500 TO 600 BED GENERAL HOSPITAL AREA APPROXIMATELY 5,000 SQUARE FEET D. R, INDICATES DRESSING ROOMS FEWER BUT LARGER ROOMS MAY BE PREFERRED IN PRIVATE INSTITUTIONS 251
Page 44
supply for the X-ray machines. Practically all types of X-ray machines use alternating current for their primary supply. In the case of direct current supply this necessitates the addition of a rotary converter with its inherent limitations. The constancy of radiation output, and there- fore also the diagnostic and therapeutic result, de- pends in no small degree upon a steady incoming line voltage. Due to the characteristics of the X-ray tube even a small fluctuation in the line voltage may cause a great variation in the radiation intensity. While there are several makes of sta- bilizers which will keep the tube current constant, independent of line fluctuations, these do not take care of the other important factor, the high ten- sion voltage across the tube. The voltage regula- tor used on ordinary power circuits acts too slowly to be of real benefit, especially in fast radiography. To minimize the voltage fluctuations, the X-ray department should have its own separate line and wherever possible also a separate transformer. No other power load should be connected to this line and transformer. For a large department it may be advisable to use a three-phase system and dis- tribute the X-ray load, usually single phase, as evenly as possible between the phases. This ar- rangement has also the advantage that it will readily take care of any future three-phase genera- tor, a type which now is not unusual in Europe. As the voltage drop in the feeder is a function of its resistance, the selection of the proper size wire is important. Table No. 2 gives the current drawn by the average single-phase 220-V. machine at various tube loads. Where several generators are used at the same time, the maximum current will be the geometrical sum of currents of the machines operating simultaneously un- der peak load con- ditions. The wir- ing chart indicates the size of wire for various currents and distances as- suming an allow- able drop of 1% between incoming service and X-ray machine. For a large de- partment it is good practice to have a common X-ray power panel pro- vided with pilot 252 SECTION AA (SEE TYPICAL PLAN) THROUGH DARK ROOM WALL SHOWING LOCATION OF GENERATOR AND FILM PASS BOX light and voltmeter, also a main switch and individual switches for each generator. The main switch permits the shutting off of all power at the same time. The individual switches are used to cut out equipment undergoing repair or in- spection. In addition, externally operated safety TABLE 2: APPROXIMATE CURRENT CONSUMP- TION BY AVERAGE SINGLE PHASE 220- VOLT X-RAY GENERATOR Line Current Type of Work Fluoroscopy Radiography Tube Load 5 Amperes 15 Amperes 28 Amperes 40 Amperes 50 Amperes 90 Amperes 160 Amperes 10 Amperes 15 Amperes 55 Amperes Therapy . どど ぴら こら こら らら らい らい トー メー ネー ミー エー ミー ミー ミー ミー ミー】 BRZBZZAZZA аа 中 4 は キサ シレ シシ シシ シシ シシ らら 一 switches аге located at the control stand of each generator. In practically all modern hospitals provisions are made for the use throughout the hospital of a small mobile X-ray machine at the bedside of the patient. Ав this machine requires more current than it is possible to obtain from standard outlets, special wiring is necessary. Three-pole recepta- cles, one pole grounded, should be located on each floor and within 40 to 50 feet of any point where it is desired to operate the bedside unit. By using 220 volts in preference to 110 volts the diameter of the wire can be smaller. The actual size can be determined by the previously mentioned tables knowing the kind of work required by the mobile generator and the distance to the in- coming service. To eliminate loose wiring across the floors of the X-ray rooms con- cealed conduits of ample diameter should be provided for various auxili- ary circuits be- tween the control stand and the dif- ferent equipment in the X-ray room. For the protection of the operator and patients against THE AMERICAN ARCHITECT
Page 45
high-tension shocks the metal fluoroscopes and tube stands should be grounded. For this pur- pose small brass plates with connecting screw should be provided flush with the floor at con- venient places and connected to a suitable ground such as a water pipe. The lighting of the X-ray department should be given careful consideration. Due to the high- tension conductors suspended from the ceiling in the X-ray rooms, care should be taken to insure ample clearance to the electrical fixtures. Wall brackets or flush ceiling units should be used where conditions permit them to be satisfactorily located. The dark room should have an ample number of wall outlets at the tank and loading table. Pro- vision should also be made for a double circuit ceiling fixture giving indirect white or colored illumination. The white light should be con- trolled by a switch located out of reach of the casual visitor. A similar fixture, but with direct illumination, should be provided in the fluoroscopic and fracture rooms. Arrangement should here be made where- by the red light can be controlled by a foot switch. It is important that the meters hanging from the ceiling in the X-ray rooms are properly illumi- nated. Lights with special reflectors mounted above the operators window will usually be found to serve this purpose admirably. All machine rooms should have an outlet for a trouble lamp and in the viewing room special 30 ampere outlets should be provided for the viewing boxes. PROTECTION AGAINST RADIATION Within a few years after Roentgen's discovery of X-rays several of the pioneers in this field suf- fered from certain harmful effects due to prolonged exposure to the rays. The radiation used today has the same dangerous properties, but we are bet- ter able to guard against them because of our improved knowledge of its nature. When prop- erly applied, in carefully designed laboratories, radiology today does not present greater hazards than many other professions. The main purpose of protection is to absorb the unwanted part of the radiation. As the absorp- tion depends upon the density of the absorbing medium, heavy materials like lead and its com- pounds, or barium plaster and the so-called ray proof rubber, are those most generally used. The protective material is placed most economically at the source of radiation, the X-ray tube. The pres- ent tendency is, therefore, also toward enclosed WIRING CHART SHOWING SIZE OF WIRE FOR VARIOUS CURRENTS AND DISTANCES ASSUMING ALLOWABLE DROP OF ONE PER CENT BETWEEN INCOMING SERVICE AND X-RAY MACHINE FOR SEPTEMBER 1929 253
Page 46
Material Density Aluminum . Z nor qr TAE 8.4 Steel 。。。。 7.8 Lead Gim Jana wasu GF he ез 3,4-4.6 Lead Rubber 2...» ener кер» messe 3.3-5.8 *Barium Plaster ............ 3:5 TConcrete 21 Red Brick . 1.9 1/16” equal to 1.59 mm. approx. Thickness giving same protection as lead at various tube voltages. 100 K.V. 150 К.У. 200 К.У. Peak Lead 60 mm. 60 mm. 70 mm. 1 mm. 120 mm. 130 mm. 140 mm. 2 mm. 4 mm. 6 mm 6.5 mm 1 mm. 9 mm. 13.5 mm. 16 mm 2 mm. 14 mm. 21.5 mm 27 mm. 3 mm. 6.5 mm. 9 mm 11.5 mm. 1 mm. 15 mm. 21.5 mm. 27 mm. 2 mm. 23.5 mm. 34 mm. 39 mm. 3 mm. 4to 7.5 mm 1 mm. 8 to 15 mm. 2 mm. 12 to 22 mm. 3 mm. 2 to 5 mm. 1 mm. 8 to 15 mm. 2 mm. 12 to 22 mm. 3 mm. 4 mm. 7.5 mm. 9 mm. 1 mm. 9 mm. 18 mm 25 mm. 2 mm. 14.5 mm. 29 mm 43 mm. 3 mm. 20 mm. 41 mm 65 mm. 4 mm. 100 mm. 105 mm 110 mm. 1 mm. 200 mm. 210 mm. 220 mm. 2 mm. 100 mm. 110 mm 120 mm. 1 mm. 200 мм. 220 mm 250 mm. 2 mm. 1/8” equal го 3.18 mm. approx *2 parts course BaSo』: 1 part fine Вабоҙ; 1 part Portland Cement TAverage mix used in building construction TABLE 3: PROTECTIVE VALUE OF VARIOUS MATERIALS tube holders or tubes with ray proof walls. In either case, a small aperture allows only the wanted fractional part of the total radiation to pass out. With this arrangement we have only to protect against the primary rays passing through the aper- ture and the secondary or deflected radiation given off by the patients, the walls, the floor or by any other object which the rays may strike. The amount of protection needed will depend upon a number of conditions, the most important of these being: Tube Voltage Tube Current Distance to the Tube Accumulative Length of Exposure Туре of Tube Туре of Tube Holder Туре of Person to Be Protected (casual visitor or person continuously in the proximity of the X-rays). Depending upon the above factors, the protec- tion will, for radiography and fluoroscopy, vary from 1/16" to 3/32" of lead or equivalent thick- ness of other protective material. For therapy, 1/8" to 1/4" of lead or equivalent is generally used. The higher values mentioned are needed completely to absorb the direct beam of primary radiation, while the lower values are considered ample where enclosed tube stands are used except 254 to stop the rays passing through the aperture of the tube bolder. X-rays, like ordinary light, pass in straight lines, so that protective covering is not needed above seven feet from the floor. The only radiation that possibly could come through would be secondary radiation which by that time would have a negli- gible intensity. Wherever vision is required lead glass win- dows of sufficient thickness should be used. Тһе protective value of the window should be equal to that of the wall in which it is mounted. Тһе edges of the window should be bevelled off to insure maximum vision, with a small size window; 10" by 12" is usually sufficient. The relation between the protective values of various materials is shown in Table No. 3. Barium plaster and ray proof rubber are used to some extent, in place of lead. Barium plaster means a considerable saving in cost, but must be very carefully applied in thin layers to avoid cracks and the protection should be tested after it is in place. Special rubber has the advantage that it does not need any surfacing and also acts as an insulator against high tension shocks; its price, however, is comparatively high. Іп any case where materials other than lead are used, sam- ples of these should be tested beforehand at the voltage at which they will be used. The practical application of ray proof mate- THE AMERICAN ARCHITECT
Page 47
rials is illustrated іп the typical plan. It will be observed that all the diagnostic X-ray rooms have 1/16 inch of lead or equivalent in floors and walls 7 feet high. If tubes completely surrounded by protective materials are used, ray proof covering is only needed in the floor, control booth and the wall next to the dark room. Both therapy rooms have 1/8 inch of lead in the floors and walls, as it is assumed that an enclosed tube holder is to be used for the deep therapy tube. An additional sheet of 1/8 inch lead 8 feet by 8 feet is placed under the deep therapy tube holder, making a total of 1/4 inch of lead to absorb the primary beam. No ray-proofing is provided in the ceiling as only secondary radiation will travel in that direction and a 6-inch concrete floor is ample to stop the small intensity diminished by the great distance. STRUCTURAL CONSIDERATION In order to minimize the effect of possible elec- trical shocks the floors in the X-ray rooms should have insulating covering such as heavy linoleum or rubber placed on wood or cork to give addi- tional insulation. If lead is used, it should be placed furthest away from the surface. No special recommendation has been made as to the storage of films, as practically all hospitals today use the acetate base, non-explosive type. If, however, it is desired to make provisions for the use of nitrate base films, a vault completely isolated from the main hospital buildings is recommended. This building should be constructed in accordance with the National Fire Underwriters Code and also in conformity with local building ordinances. The fluoroscopic and dark rooms must, nat- urally, function with the windows closed to pre- vent light entering. Artificial ventilation is there- fore necessary. Generally, louvers to the hall and outside together with forced ventilation are used. Provision should also be made for ventilating the machine rooms where the electrostatic fields break down the air, producing an undesirable amount of ozone. Where it is necessary to have the dressing room partitions go to the ceiling these rooms should have light proof ventilators. Contrary to tradition, the X-ray rooms can have light and cheerful coloring. Light blue or green are the preferred shades. In rooms where there are overhead high tension conductors, the ceilings should be the same color as the walls to hide the accumulation of dust on the parts nearest to the high tension conductors. A review of radiological developments during the last decade clearly indicates that still further Progress may be expected within the next few years. While it is not possible to prophesy what will be the exact future demands from the X-ray department, there is no doubt that a spacious and flexible layout is essential to maintain a high de- gree of efficiency for years to come. This idea should be paramount in the mind of the architect planning a new roentgenological department. The writer wishes to express his sincere appre- ciation to the several prominent roentgenologists who readily have given their valued counsel іт the preparation of this article. References: “Methods and Problems of Medical Education (Twelfth Series)." The Rockefeller Foun- dation, 1929. “The American Hospital of the Twentieth Cen- tury,” by Edward F. Stevens, 1928. "Коепгдепоіоду," Бу С. W. C. Kaye, 1928. "Roentgen-Rag Protection," by L. S. Taylor. American Journal of Roentgenology, July, 1929. FOR SEPTEMBER 1929 255
Page 48
| % EDITORIAL COMMENT $ ACHIEVEMENT HE June-July, 1929, issue of the New York Building Congress News contains a short arti- cle entitled “R. D. Kohn as Seen by Himself." Mr. Kohn, president of the Building Congress, wrote the article in response to a request for biographical information about himself. Mr. Kohn does not hesitate to say that he was born in New York City on May 12th, 1870. After briefly outlining his early education and later his student days in archi- tecture and work with the Housing Division of the Emergency Fleet during the war, he outlines the organization of his office which consists of a group of associated architects. In closing, Mr. Kohn states: “Among the achievements I still look for- ward to there is one above all others. It is that I may some day do a really beautiful piece of work; one that, at its completion, will satisfy me aesthet- ically. We suppose that this is the underlying principle which, if admitted, stimulates the ma- jority of architects to go on whether "jobs" are many or few, interesting or distasteful, large or small, or cheap or costly. One cannot help won- dering whether many architects achieve this am- bition, for the most difficult person to satisfy in this matter is the creator. Richard Upjohn, Stanford White, Charles Mc- Kim, Willis Polk and Bertram Goodhue, among others, must have realized or come very close to realizing this ambition. It can well be imagined that the late Milton Medary achieved something that satisfied him aesthetically in the Bok Singing Tower at Mountain Lake, Florida. After all, the number of architects who realize this lifelong dream are comparatively few. To many, and their name is legion, it remains only a dream, often for want of opportunity or the combination of factors that makes a vision of an ideal a reality. That these men keep on day in and day out speaks well for their steadfastness of purpose, courage and— backbone. A few fall by the wayside, but the Com ела majority keep their dream of achieving а really fine monument constantly before them. ote TALL BUILDINGS Most of us can recall when “tall” buildings were eight, nine or perhaps ten stories high. Build- ings of thirteen, fourteen or fifteen stories were skyscrapers, until the Woolworth Building was erected. Thereafter we became very much accus- tomed to twenty-story buildings, and even thirty- story buildings ceased to cause much comment and are now relegated to the real estate news pages in the back of the newspaper among the advertise- ments. In New York City the proposed Larkin Building of over one hundred stories, announced about two years ago, was sufficiently daring to gain space in the second, third or fourth pages of a daily or a column in the Sunday feature section. If one continues to hear rumors that the project is still being considered, that is the nearest that it seems to realization for the present. The Chanin Building of fifty-eight stories became a reality, and its sixty-eight story neighbor, the Chrysler Build- ing, is rapidly rising heavenward, a spire of steel followed by a mass of brick and stone. The flag does not yet fly from the topmost steel column, but we read that a building eighty stories high is proposed for the corner opposite the Chanin and the Chrysler Buildings. A recent morning news- paper devoted a third of a column to the announce- ment, which would indicate that buildings fifty to eighty stories in height still have an element of news. This tower would be twenty-three stories higher than the Woolworth Building and five stories higher than the proposed Crane Tower in Chicago. The Eiffel Tower in Paris would, how- ever, still remain the tallest man-made structure. Oh, yes, the cost of the eighty-story tower is men- tioned in round figures as $25,000,000. Awa GE == afi № a THE AMERICAN ARCHITECT
Page 49
HOUSE FOR V. Т. BISHOP BEL-AIR, CALIFORNIA GORDON B. KAUFMAN Architect FOR SEPTEMBER 1929 257
Page 50
Ж, ль =>" Г BEL-AIR, CALIF ARCHITECT T. BISHOP, HOUSE FOR W KAUFMAN, GORDON B THE AMERICAN ARCHITECT
Page 51
Photo by W. М. Clarke HOUSE FOR W. T. BISHOP, BEL-AIR, CALIF GORDON B. KAUFMAN, ARCHITECT FOR SEPTEMBER 1929 259
Page 52
Засомо FLOOR PLAN Seale ==," HOUSE FOR W. T. BISHOP, BEL-AIR. CALIF. GORDON B. KAUFMAN, ARCHITECT FIRST Діор. PLAN Scale = SS." THE AMERICAN ARCHITECT
Page 53
HOUSE FOR Т. FENTON KNIGHT LA CANADA, CALIF. HENRY C. NEWTON AND ROBERT D. DENNIS Architects | x a Y is Oe, N Е i dnd / N — ras x : ет. / ( > 2 = 73 5 "Pm £ — s x wt a Hp та ses CADAT, apace „т. FENTON. i pers 18 ja Max 7 Henry Carlon (выб ew. Фобоса Darti Parra: Робот. FOR SEPTEMBER 1929 261
Page 54
by Miles Berne HOUSE FOR T. FENTON KNIGHT, LA CANADA, CALIF. HENRY C. NEWTON AND ROBERT D. DENNIS, ARCHITECTS THE AMERICAN ARCHITECT
Page 55
Miles Berne Photo by HOUSE FOR T. FENTON KNIGHT, LA CANADA, CALIF. HENRY C. NEWTON AND ROBERT D. DENNIS, ARCHITECTS FOR SEPTEMBER 1929 263
Page 56
SLDALIHDUV ‘SINNHG ‘а ІМНЯОЧ ANV NOLMAN 2 AUNJH --ЧІТУЭ VGVNVO VT .LHDINM NO.LNH4 `L моч ISAO THE AMERICAN ARCHITECT 64 2
Page 57
SPECIFICATIONS Communications relative to specifications addressed to THE AMERICAN ARCHITECT will be answered, in the pages of this department, by H. R. Dowswell, of the office of Shreve, Lamb © Harmon, Architects. EJ HE New York Building Congress Standard Specifications for Carpentry have had the bene- fit of criticisms and suggestions by both the Master Carpenters’ Association of New York and the Lumber Association. The Standards Com- mittee therefore feels that these specifications should help to clear up many of the misunderstandings which have heretofore arisen in this division of the work. These specifications, as others pre- viously published, require that the Architect, in Part A, make decisions on items which vary for different buildings. The specification writer should particularly note Paragraph 7 regarding "nominal dimensions" and Paragraph 17. These paragraphs definitely accept “trade sizes” unless ALA. Divisio. 19, large scale or full size details are issued for bidding. The remaining paragraphs need no special com- ment except perhaps Paragraphs 100 to 106. Paragraph 102 is important. If the Architect desires to inspect millwork, such inspection, to be of value, must be made before priming or back painting. The Standards Committee do not at the present time propose to issue a standard specification for Finishing Hardware. The selection of hardware for any building depends upon the sum which can be appropriated and the personal likes of the Architect and Owner. Paragraph No. 100 there- fore assumes that the finishing hardware will be delivered to the sub-contractor applying same. STANDARD FORM or THE New York BUILDING CONGRESS, Eprriox оғ 1929 COPYRIGHTED ву THE New YORK BUILDING CONGRESS New York Building Congress Standard Specifications for CARPE? ITRY PART B. General Conditions. 1. GENERAL CONDITIONS OF THE Сохтваст of the Ameri current edition, shall form a part of this Division, together with the Special Con- ditions to which this Contractor is referred. Arbitration Clause. General stitute of Architects, > an Institute of Architects Condiions 2. Any dispute or claim arising out of or relating to this Contract, or for the breach Arbitration thereof, shall be settled by arbitration. Arbitration shall proceed under the require- Clause ments specified in the General Conditions, current edition, of the American Institute of Architects; or under the Rules of the Arbitration Court of the New York Build- ing Congress, or of the American Arbitration Association, and judgment upon an award may be entered in the court having jurisdiction. One of these methods of arbi- tration shall be chosen at the time of the signing of the Contract, or, if not then determined, the choice of these methods shall beat the option of the party asking for arbitration, Scope 3. The following requirements in regard to materials and workmanship specify theScope required standards for furnishihg of all labor, material and appliances necessary for the execution of all Carpentry, Framing, Millwork and Rough Hardware. Relations with Other Trades. 4. These requirements, however, form a part of the Contract only insofar as they Relations with describe items mentioned in Part A of this specification or as indicated on the Con- Other Trades tract drawings. Temporary Enclosures. 5. This Contractor shall coóperate with contractors for other trades with which hisTemporary work comes in contact. Where anchors, nailing pieces, frames or other carpentry Enclosures work is to be built into masonry, the material shall be furnished by this Contractor in ample time to avoid delays. Subsequent cutting or alterations required through failure in this regard shall be executed at this Contractor's expense. Recommended for use by the New York Chapter, ALA. Approved by the Master Carpenters’ Association of New York FOR SEPTEMBER 1929 265
Page 58
New York Building Congress Standard Specifications --САКРЕМТКҮ--Сопппиеа. Materials. ы К А " 6. Where temporary enclosures for openings or other portions of the work are specified Materials to be furnished under this Division, they shall be of the extent and be constructed as noted under Part A. - 7. АП rough carpentry, framing lumber and timbers such as girders, beams, sills, plates, joists, rafters, studs, sleepers, grounds, bucks, sheathing, underfloors, etc., shall be of the kinds and nominal dimensions specified under Part A, well seasoned according to use and, unless otherwise specifically noted under Part A, of commercial association grades conforming to the “American Lumber Standards” as follows: (a) All lumber less than two (27) inches thick, used structurally, and all studding two (27) inches by four (47) inches (nominal) shall be not less than grade No. 2 common yard lumber. A (b) Lumber, four (47) inches to two (2”) inches in thickness, used for load bearing pur- poses, shall be not less than grade No. 1 or No. 2 common yard lumber, as specified under Part A. (c) Lumber five (57) inches and thicker, used structurally, shall not be less than com- mercial grades conforming to common structural material. (а) AI structural timbers to be designed for the higher working stresses allowable for commercial structural grades, conforming to basic grades for select structural ma- terial, shall be grade-marked or trade-marked or otherwise identified by authenticated certificate as gualifying for such higher working stresses. 8. Materials for finished carpentry, which includes interior and exterior woodwork, shall be of the species and dimensions specified under Part A or indicated on the Contract drawings and shall conform to the following reguirements: 9. Unless otherwise specified under Part A, material for painted finish may contain such sound tight pin knots as will not detract from the finished appearance of the work and shall be free from heavy sap-stain, worm holes, exceeding 1/16 inch, or other defects impairing either the durability or appearance. 10. Material for natural, stained, varnished, lacguered or waxed finish, unless otherwise specified under Part A, shall be free from knots, shakes, sap, stain, worm holes or other defects impairing either durability or appearance. 11. Materials having marked difference in color shall, in addition to conforming to the reguirements specified under Paragraph 10, be selected to obtain uniform color. 12. Where vertical grain is specified under Part A, the material shall be free from coarse pores. 13. Where, under Part A, panels or other portions of the work are specified to be selected for figure and grain, the material shall be carefully matched for figure and color. 14. АП material, for exterior finished woodwork, shall be thoroughly air dried; interior finished woodwork shall be kilndried and protected from moisture. Fireproofed Wood. 15. Where, under Part A, fireproofed wood is specified, the process used shall be such as Fireproofed will produce results acceptable to the local Building authorities having jurisdiction. Wood Tt shall be the duty of this Contractor, as a part of his Contract, to obtain certificates of approval from the local Building Department. Where tests are reguired in order to obtain such certificates, all expense in connection therewith shall be borne by this Contractor, as a part of this Contract. Handling and Protection. 16. АП exterior and interior finished woodwork shall be protected from the weather Handling while in transit from point of production or fabrication to the building; when de-and Protection livered at the site it shall immediately be placed under cover and be adeguately pro- tected from the weather. Kilndried material shall not be stored or erected in wet or damp portions of the building or in sections where plastering, terrazzo or similar m is to be executed until such work has been completed and become reasonably ry. Sizes and Thicknesses. 17. АП sizes and thicknesses specified in either Parts A or B of this Division shall be in- Sizes and terpreted in terms of American Standard Association lumber and moulding rules, Thicknesses except where the Contract drawings show sizes of members and profiles of mouldings at large scale or full size. In such cases the Contract drawings shall be followed not- withstanding any trade standard rules ог customs to the contrary. Shop Drawings. 18. Where so specified under Part A, this Contractor, before proceeding with any finished Shop carpentry work, shall submit to the Architect, for approval, prints of shop drawings Drawings 266 THE AMERICAN ARCHITECT
Page 59
еткін FFE New York Building Congress Standard 5ресійсайпопв--САКРЕМТЕҮ--Сопппиеа. in duplicate, illustrating, in detail, the construction of all doors, frames, sash, panel- ing and special work. 19. These drawings shall be based upon and follow the Contract drawings and scale and full size details. “They shall be modified and revised as may be required by the Architect for the purpose of more perfectly carrying out the intent and meaning of the Architect's drawings and specifications. When these drawings have been ap- proved, all work shall be executed in accordance with them. 20. After approval, this Contractor shall supply the Architect with two additional prints of each drawing. He shall supply additional prints as may be required to secure the coöperation of other trades, at the cost of reproduction. Workmanship—Rough Carpentry. 21. Joists, beams, girders and rafters shall be set with their crowning edge upwards and, Workmanship where bearing on masonry walls, shall be splayed not less than three (3") inches іп —Rough their depth, with bearings of not less than four (4") inches. Each tier of joists bearing Carpentry on walls shall be tied to masonry walls at intervals not exceeding four (4') feet by metal anchors, furnished and installed by this Contractor, not less than 1⁄4 of an inch by 174 inch cross section and at least twenty-four (24") inches long securely spiked near the bottom of the joists and provided with split and upset ends or other approved means for building into masonry. Joists parallel to masonry walls shall be provided with similar anchors at intervals not exceeding six (6”) feet, engaging three (3) joists. Upset and “Т” ends on anchors shall develop the full strength of the anchor strap. . Framing in all cases shall be kept at least two (2”) inches clear of all fireplace breasts, hearths, chimneys and flues. 23. Where studding, forming bearing partitions or walls occurs over sills, girders or plates, they shall extend down to these and be securely spiked to bearings and, where possible, to the floor joists as well. Joists carrying parallel bearing partitions shall be doubled under them. Bearing partitions at right angles to joists shall rest on doubled plates. Non-bearing partitions may rest on single plates, laid over sub-floors. АП stud bearing partitions and walls shall have doubled caps and cross bridging of same material as studs, at intervals not exceeding six (6') feet in height securely nailed with at least two nails at each end. 24. In general, studs shall be doubled at all corners and angles, and sides, and heads of openings, Truss over all openings wider than three (3’) feet, and over all openings in bearing partitions. 25. Where framing out is necessary, both header and tail beams shall be supported with approved wrought iron joist hangers or stirrups furnished and installed by this Con- tractor. Where more than two joists frame into a header, both trimmers and headers shall be doubled in size. Bridging. 26. Bridge between all joists at intervals of not less than eight (87) feet with a double Bridging row of cross bridging. Except where special steel or iron bridging is specified under Part A or approved by the Architect, material for bridging shall be of spruce not less than 11/16” x 254” and shall be nailed with two 8d nails at each bearing. Roof Sheathing. 27. Roof sheathing shall consist of close sheathing or shingle lath as specified under Roof Part A. heathing 28. Where close sheathing is specified it shall consist of tongued and grooved or ship-lap boards of material noted under Part A, dressed to an even thickness not less than 25/32 inch thick, driven tightly together, breaking joints at least every twenty-four (24”) inches and nailed with two nails at every bearing. 29. Where shingle lath are called for, they shall consist of material of the dimensions specified under Part A, spaced to suit the weatherings“of the finished roofing, and nailed at every bearing. All joints, except where sheathing is end-matched, shall be made over bearings. Wall Sheathing. 30. Wall Sheathing shall consist of materials as specified under Part A. Where wood Wall | sheathing is specified, the boards shall be dressed to an even fhickness, ont less than Sheathing 25/32 inch thick, laid diagonally with close joints and nailed at every bearing with at least two nails. All joints, except where end-matched sheathing is used, shall be made over bearings. Grounds. 31. Permanent grounds shall be provided wherever required to afford proper nailing oi Grounds bo ы ЕОК $ЕРТЕМВЕК 1929 267
Page 60
New York Building Congress Standard Specifications -CARPENTRY—Continued. all finished Carpentry and, where so stated under Part A, for the securing of metal covered wood or hollow metal trim. 32. Where so specified, temporary grounds for the work of other trades, shall be in- stalled in the rooms or spaces enumerated under Part A. | 33. АП grounds shall be dressed to sizes required on details, and shall be secured in posi- | tion in a manner absolutely rigid, straight, level, even and plumb, so that the surfaces of the finished coat of plastering shall be flush wtih the face or edge of all grounds 34. Grounds generally shall be 54 inch by 2 inches in size, where same are applied to bloc work, and 34 inch x 2 inches where applied to lath work. Grounds shall be in as many lines as required to properly set trim. Floor Sleepers. 35. Where, under Part A, floor sleepers are called for, they shall be of the material and Floor sizes specified and shall be secured to the floor construction by metal clips or tie wire Sleepers supplied and installed by this Contractor. Unless otherwise specified under Part А, sleepers shall be set at sixteen (16”) inch centers, except where special conditions require closer spacing. They shall be carefully levelled and blocked, special attention being paid to see that there will be no sagging at ends or anywhere throughout their length. Where underflooring is specified to be laid diagonally, headers shall he in- stalled where necessary to provide a continuous bearing. 36. Form transverse runs, where directed, to accommodate pockets for electric conduits, steam piping, plumbing and other service piping. 37. After sleepers are laid, cinder concrete fill will be placed between sleepers, under another div Underflooring. 38. Underflooring shall consist of square edged or tongued and grooved boards of ma- Underflooring terial thickness and widths specified under Part A, dressed to an even thickness, not less than 25/32 inch thick, and face nailed with at least two nails at each bearing. 39. Unless otherwise specified under Part A, underflooring shall be laid at right angles to joists or sleepers. End joints, except where end-matched boards are used, shall be made over bearings. Joints between boards shall be tight or open as specified under Part A. A 40. Where tile floors are to be placed over wood joist construction, the tops of joists shall be trimmed to a bevelled edge, and a close under floor cut in between three (3”) inches below the top of joists. Wood Furring. 41. Wood furring, unless otherwise stated under Part A, shall consist of 34 inch x 2 inch Wood Furring soft wood, of kind specified under Part A, dressed to an even thickness, spaced twelve (12") inches on center. 42. Where wood furring is specified to be applied to masonry surfaces, a secure nailing shall be provided by drilling and plugging, except where metal nailing plugs are specified under Part A. 43. Where, under Part A, metal nailing plugs are specified, they shall be furnished by this Contractor, before masonry is built and will be built in by the Contractor for Mason- ry at this Contractor's direction. 44. Where wood furring is to be secured to wood framing, it shall be firmly nailed at every bearing. 45. Where wood bucks are called for, they shall be of the plain or rebated type of ma- Bucks terial and sizes specified under Part A. Legs shall be dadoed into heads and heads pointed at both ends. Where rebated bucks are specified, they shall be the full width of the partition plus the thickness of plaster on each side and shall be rebated 1/2 inch to receive partition blocks. 46. Bucks shall foot upon the floor arches or on top of concrete fill, as may be necessary, but shall be of sufficient length to permit either form of construction and shall have continuous footing piece 74 inch thick by the width of the buck. АП bucks shall extend in one piece, the full height of the openings, and shall be provided with No. 16 gauge galvanized iron crimped anchors, 1%; inches wide, at least three to each jamb. 47. The location of partitions receiveing wood bucks will be established on each floor under another division, either by placing pilot blocks or marking center lines of corridors on floor slabs or walls. Accurate dimensions and levels will also be fur- nished giving the position of each buck. This Contractor will be required, as a part of his Contract, to accurately locate all door bucks in accordance with the information given. 268 THE AMERICAN ARCHITECT
Page 61
New York Building Congress Standard Specifications —CARPENTR Y—Continued. 48. Bucks shall be accurately set, plumb and true and properly stayed until built in. Finished Carpentry. 49. In general, all finished carpentry shall be finished and assembled at the mill, as far as Finished practicable, and delivered at the building ready to set in place. The material shall Carpentry be worked in the best manner known to the trade; mortised, tenoned, dowelled, blocked and glued together so as to avoid the use of nails as much as possible ; mould- ings cleanly cut, sharply defined and mitres accurately made. Plain butt joints without an approved device for preventing separation at joints will not be accepted. Where nails and screws are necessary they shall be concealed. Unless otherwise speci- fied under Part A, all surfaces shall have a smooth machine finish. 50. Panel work shall be assembled in such a manner as to allow free movement of panels Siding. 54 Where applied mouldings are called for, they shall be secured to stiles and rails. Unless otherwise specified under Part A, panels shall be built up of veneers as speci- fied for doors with stiles and rails solid. All panels shall be primed or stained before being framed into place. . All frames and finish of every sort shall be put up plumb or level, straight and true; trim shall be put up with proper grounds in every case and firmly secured to same. . Interior frames, trim or other finish of any sort shall not be set until the plaster is on and dry, in the judgment of the Architect. . All work shall be fitted and scribed to plaster or other finished work in a careful manner, so as not to injure the surface in any way. Where plastering or other work has become needlessly damaged or disturbed by this Contractor, it shall be made good at his expense and іп а manner approved by the Architect. All nailing shall be blindnailed wherever possible, but, where not possible, the nailing shall be so located and driven as not to be visible in the finish. . Exterior siding shall be furnished in long lengths of the material, thickness and Siding width specified under Part A. All siding shall be placed with edges true to the hori- zontal, butted closely and neatly against window and door frames or trim, be ac- curately mitered at corners with intermediate joints vertical and be nailed securely at every bearing. Exterior Wood Trim. 55. Exterior wood trim shall conform to sections and sizes indicated on scale and detail Exterior Stairs. 56. un 60. 61. 62. 7. drawings and shall consist of materials and be prepared to receive finishes specified Wood Trim under Part A. Stairs shall be constructed with open or closed strings as noted under Part А or Stairs indicated on the Contract drawings. Where open string construction is called for, rough carriages shall be provided con- sisting of material as specified for general floor framing not less than two (2") inches thick and spaced not more than 2 feet-O inch center to center in the width of the stair. These carriages shall be accurately cut to the rise and tread required for the stair and securely and rigidly fixed in place ready to receive finished strings, treads and risers, . Finished strings, treads and risers shall be of material specified under Part А. Where closed strings are specified or shown on Contract drawings, they shall be dadoed to receive treads and risers. Where an open outside string is specified or shown, the string shall be scribed to underside of treads, and be accurately mitered to the risers. . Where open strings are called for, the treads shall be firmly secured to carriages, have nosing formed as indicated on details, returned on outside string, mortised for bal- usters, grooved on under side at the front to receive risers, and tongued at back edge into risers. Risers, on open string construction, shall miter with outside string, be tongued into underside of tread, grooved at lower edge to receive tread and finish with moulding as indicated. Where closed string construction is called for, the treads and risers shall be housed into the strings and tightly wedged and glued. Тһе risers shall be tongued into tread above and grooved to receive tread below. Outside strings shall be panelled or plain as shown on Contract drawings, finished on top with a moulded shoe prepared to receive balusters and with scribe or soffit mould as required. Тһе wall string shall be finished on top with a scribe mould or arranged to form base for panelling as indicated. FOR SEPTEMBER 1929 269
Page 62
New York Building Congress Standard Specifications -CARPENTRY—Continued. 63. All strings shall be shaped to conform to contour of stair well, as indicated, with all necessary ramps and easements. Newels shall be panelled, turned or plain, finished with cap and drop as indicated on Contract drawings and rigidly secured to stair construction. Newels on stairs of closed string construction shall have intersecting strings, treads, and risers housed into them. 64. Hand rails shall be moulded in accordance with details, grooved or bored to receive balusters, provided with fillers where grooved, secured to newels with concealed bolts, formed with all ramps, easements and goose necks specified under Part A or in- dicated on Contract drawnigs and be securely and rigidly erected in place. 65. Where wall rails are called for, brackets for support of same, will, unless otherwise specified under Part A, be furnished and installed under another division. Where wood mats or grounds to receive wall rails or wall rail brackets are specified, they shall be furnished and installed by this Contractor. 66. Balusters shall be square, turned or otherwise shaped in accordance with details and spaced as indicated or specified. On stairs of open string construction, the lower end of balusters shall be dove-tailed into treads. Finished Floors. 67. The finished flooring shall be of the materials, grades, face and thicknesses specified Finished under Part A and shall be air dried, kilndried and accurately milled. Floors 68. Unless otherwise specified under Part A, all finished flooring shall be tongued and grooved and end matched. Flooring 25/32 inch and greater in thickness shall be hollow back; flooring less than 25/32 inch in thickness shall be grooved in the back. 69. Finished flooring shall not be delivered to the building in damp or wet weather nor shall it be stored in newly plastered rooms or otherwise exposed to dampness. 70. Finished flooring shall not be laid until after all partitions have been erected and plastered and until plastering and masonry work is dry. 71. It shall be the duty of this Contractor to examine the building and assure himself that the underflooring, plastering and the building generally are in proper condition to receive flooring. He shall see that the underflooring or nailing concrete, where used, is level, free from plaster droppings, pro jections or dampness and shall report to the Architect or General Contractor any defects which would tend to prevent the laying of a finished floor of the character specified. Failure to make such an examination and report shall be construed as an acceptance of building conditions and prepara- tory work. 72. This Contractor shall lay between the underfloor or concrete base and finished floor an insulating material, waterproof where specified under Part A and weighing not less than twenty (20) pounds per 100 square feet. The insulating material shall lap at least two (2”) inches at all joints. Direction of Boards. 73. Unless otherwise specified under Part A or indicated on Contract drawings, flooring Direction of boards shall run the long dimension of the room or space. Boards Borders. 74. Where, under Part A, borders are called for they shall be laid as specified or in- Borders dicated on Contract drawings. All joints between borders and floor strips shall be tongued and grooved ; butt joints will not be accepted. Nailing. 75. Each piece of flooring shall be well driven into position. All tongued and grooved Nailing flooring shall be blind nailed, using nails and spacing as follows: Flooring 25/32 inch thick, 8d. steel cut light flooring nail, 12 inches to 14 inches apart. Flooring 15/32 inch thick, 6d. bright wire finishing nail, 8 inches to 10 inches apart. Flooring 11/32 inch thick, 4d. bright wire casing nail, 6 inches to 8 inches apart. Scraping and Surfacing. 76. After laying, all flooring shall be swept clean, scraped lengthwise of the grain and Scraping and rubbed down with No. 132 sand-paper, again swept and the dust removed with a Surfacing soft cloth. Unless hand scraping is specifically called for under Part A, a machine scraper may be used. 77. After scraping and cleaning, all finished floors shall be completely protected by this Contractor with heavy building paper. This protection paper shall be maintained by this Contractor until the contractor for painting and finishing commences his work. 270 THE AMERICAN ARCHITECT
Page 63
New York Building Congress Standard Specifications - CARPENTR Y—Continued. Door Frames. 78. Exterior and interior door openings shall be fitted with frames for hinged or sliding Door Frames Doors. 28 85. 86. 87. 88. doors as indicated on drawings, constructed in accordance with details, of kilndried stock of grade, materials and dimensions specified under Part A. These frames shall be rebated or fitted with stops, provided with jamb and head lining, or finished the full thickness of walls or partitions and arranged to receive trim or scribe mould on one or both sides in accordance with detail drawings. Frames shall be rigidly blocked, wedged and firmly secured to bucks or rough studding. . Doors shall be of thickness given under Part A and of designs shown on Contract Doors drawings. . Generally the construction shall conform to the following requirements, but Con- tractor desiring to furnish doors produced by manufacturers favoring special methods may submit same to the Architect for approval. . Exterior doors shall be solid or veneered as specified under Part A. Where veneered doors are specified, the stiles and rails shall have 3/8 inch thick veneers applied to cores built up of 7% inch strips and put together with waterproof glue. Doors, ex- posed to the weather when open, shall have the top edge covered with metal by this Contractor, as specified under Part A. . Interior panelled doors shall have stiles and rails veneered with % inch thick veneer, sawed or rotary cut as specified under Part A. The veneers shall be applied over built up cores of white pine or chestnut and finished оп the outside edges with a 3⁄4 inch strip of material matching face veneers. Panelled doors shall have plain or raised panels and with flush or raised mouldings as specified under Part A or indicated on Contract drawings. . Flush doors shall consist of slab or framed up construction, as specified under Part A. . Slab construction shall consist of glued up cores of 7 inch strips, cross banded with 1⁄4 inch thick veneers and faced vertically on both sides with 1/20 inch thick veneers and, on vertical edges, with 34 inch edge strips. Framed up construction shall consist of stiles, rails, and flush panels, all of 74 inch core construction, cross banded and finished with face veneers and edges, as spec- ified for slab doors. Sheathed doors shall be constructed with cores as specified for framed up flush doors and shall be faced on both sides with material of thickness and width specified under Part A. Double leaf single swing doors shall have moulded astragals, unless otherwise shown on details. Double swing doors shall have rounded meeting stiles. Glazed doors shall be provided with moulded glass stops on room side and where muntin divisions are shown, they shall be of wood with moulded glass stops unless otherwise specified or detailed. Window Frames. 89. Window frames shall be constructed for sliding, hinged, pivoted, or fixed sash, as Window indicated on the Contract drawings, and of materials specified under Part A, using Frames 90. 91, clear grades for exposed parts and merchantable grades for concealed portions. Where vertical sliding counter weighted sash are called for, the frames shall be constructed with pulley stiles, parting strips, inner and outer casings, back linings (forming weight boxes), pendulum strips and sash stops, except where stops are specified to form part of interior trim, and outside scribe moulds. The frames shall be fitted with sash pulleys of side or overhead type specified under Part A, and be provided with an acceptable method for access to weight boxes. Frames for horizontal sliding, hinged, pivoted or fixed sash shall be rebated or other- wise constructed to permit the operation indicated or accommodate special hardware specified under Part A. . All frames for openings in masonry walls shall be provided with exterior scribe moulds. These shall be left removable until after joint between frame and masonry is caulked and pointed and then secured permanently in place. Caulking, unless specifically noted under Part A, will be executed under another division. . Sash shall be constructed of kilndried stock, of grade and material and thicknesses Sash specified under Part A, moulded and checked in accordance with detail drawings, mortised, tennoned, glued and pinned in accordance with the best trade practice. FOR SEPTEMBER 1929 271
Page 64
New York Building Congress Standard Specifications —CARPENTRY—Continued. Counter weighted sash shall be hung with sash chain or cord of the kind specified under Part A and of size suited to weight of counter weight. Counter weights shall be of cast iron; or of lead where conditions of heavy sash or narrow mullions те- quire that lead weights be used, as specified under Part A. Trim. 94, The material, character and extent of the trim shall be as specified under Part A. Trim Where splines, dowels or a special device, at joints in architraves or between archi- - traves and plinth blocks are specified, these shall be furnished—otherwise architraves shall be neatly and accurately mitered at corners and butted on plinths. 95. When stools are called for, the stools shall be tongued into the window sills. Where aprons are required, the stools shall be plowed to receive them, Stools and aprons shall, unless otherwise specified or detailed, be finished with a return at either end. 96. Where jamb and head linings are called for, they shall be plain or paneled, as speci- fied under Part A or indicated on Contract drawings. The inner edge shall be tongued into shoe heads or window frames and the outer edge finished flush with plaster or jointed to wall paneling, where panel ng occurs. 97. Where sash stops are specified under Part A or indicated on Contract drawings to form part of interior trim, they shall be secured to the frames with brass screws and adjustable countersunk washers, furnished as part of the finished hardware, Saddles. 98. Where wood saddles are required, they shall be of materials specified under Part A, Saddles and in locations listed or indicated on drawings. Unless otherwise specified or detailed, saddles shall be five-eighths ( Ук") of an inch thick above finished floor, line with edge of the trim on the door side and extend beyond the door the full width of door stop, or, where rebated frames occur, not less than two (2”) inches. Miscellaneous Fittings. 99, Miscellaneous fittings such as mantels, cupboards, bookcases, cabinets, shelving, hook Miscellaneous strips, hanging rods, etc., shall be constructed of materi specified under Part А Fittings and in the manner indicated on detail drawings. The standard of construction and finish shall conform to the requirements specified under paragraphs 49 to 53, in- clusive. Back Painting and Priming. 100, Where so specified under Part A, this Contractor shall prime and back paint all Back Painting exterior frames, sash and exterior and interior trim. and Priming 101. Where, under Part A, this Contractor is required to back paint interior trim designed for stained, waxed or varnished finish, he shall paint all concealed surfaces with one heavy coat of dampproof paint. Where so specified under Part A, the back of finished flooring shall be similarly painted. 102, All priming and back painting shall be applied before leaving the shop. This Con- tractor, however, shall notify the Architect at least one week before the work is | ready for priming or back painting, so that if desired, an inspection may be made of | the unpainted work. | 103. Where so required under Part А, this Contractor shall provide at his shop a room of satisfactory character and sufficient size to permit the Painting Contractor to apply the finish before delivery at the building. When this is required, this Contractor shall notify the General Contractor or the Painting Contractor when the finished wood work is ready for finishing. Hardware. 104. This Contractor shall provide and apply all rough hardware required for the proper Hardware execution of all Rough and Finished Carpentry. Rough hardware shall include tracks and hangers for sliding and accordion doors and metal standards for the W. С. stall divisions, where same are specified to be constructed of wood. | 105. Не shall also apply all finished hardware and shall obtain from the Contractor sup- plying “Finished Hardware” complete information as to type and sizes and make all allowances necessary to properly receive the hardware to be used. 106. The finishing hardware to be applied under this Division will be delivered to this Contractor at the building. He will be required to receipt for same and shall assume full responsibility for all hardware so received until application and acceptance of the work in this Contract. R M R THE AMERICAN ARCHITECT
Page 65
Apartment building, Fullerton Avenue and Clark Street, Chicago. McNally & Quinn, Architects. The modern trend in texture and design for building fac- ing and ornament is most effectively accomplished with Northwestern terra cotta. Use this versatile material to produce original design, rich color, va | АҒЫ» unique texture, permanent beauty. МОВИ HWE SHE IRN TERRA COTTA m MA DE hi : POLA Е DENVER. 510015. CHICAGO CHICAGO HEIGHTS P3 AS FOR SEPTEMBER 1929 11
Page 66
W BOOK REVIEWS a HANDBOOK OF GREEK 8 ROMAN ARCHITECTURE HERE have been few books written on the architecture of Greece and Rome which are so free from pedantry, as clear and concise in the statements of facts and as choice in the selection of material as Robertson's Handbook of Greek and Roman Architecture. The aim of the book is by no means new, but the presentation is so natural and inevitable, and the deductions seem so logical and unquestionable that it is a joy to read it. This is one of the few technical books which one can open almost anywhere at random and find something interesting. The author states that his knowledge of architecture is mostly de- rived from long study of English and foreign publications and monographs, an admission which few authors seem willing to make, and it is typi- cal of the breadth of the author's vision that he could accept help of this kind and still preserve the balance of judgment on the different periods. Eighteen centuries ago one magnificent architectural tradition ruled the whole basin of the Mediterra- nean and extended down toward the barbarians, and that tradition, notwithstanding the enormous development of succeeding centuries, has main- tained its place and is the criterion for nearly everything that has been done since. An appre- ciation of this is what makes the book so valuable. The book is fully illustrated by very discrimi- nating plans and sections and by a multitude of photographs, not encumbering the book or in- truding into the general scheme but illustrating what the author is trying to tell. There is an excellent analysis of the construction and of the plan of the dome of the Pantheon at Rome which does not altogether agree with Choissy and brushes aside some of the traditions about the way the Romans used concrete in their domes. There is a chapter on Town Planning, but this is of less interest because, after all, the Greeks had no idea of what we would call Town Planning today; axes, through-ways and squares did not exist; and the Romans were hardly any better. The Imperial City at its best was a mess and a jumble and group planning on a monumental scale simply was not. . considered in those days. The book is for the lover of architecture—one especially would be responsive to the fineness of 12 Greek art. It is supplemented by an excellent list of known buildings giving dimensions, dates and almost a synopsis of the whole subject. There is also a complete bibliography, a glossary of archi- tectural terms and a carefully prepared general in- dex. All of these help amazingly in an under- standing of this thoroughly admirable work. A Handbook of Greek and Roman Acchitecture, by D. 8. Robertson, М. A. New York: The Mac- millan Company. 406 pages, illustrated, size 6 1/2 x 91/2. $10.00. ate DAEDALUS AND THESPIS HE author states in his preface that this vol- ume has been a long labor of love. One can quite believe it. It is a fine thing that some one will do just what has here been wrought out so conscientiously. It includes a study of practically all of the important Greek monuments and pre- sents quotations from the dramatic poets that explain or refer to each structure. No review can be adequate to give a correct idea of the wealth of material which is presented in such usable shape. It must be dug into, pondered over, allowed to grow on the mind, to be read and re-read, and for those who have the time, it would be well worth while. In fact, also for those who have not the time it might be a healthful antidote for the mod- ern venom of haste. At first reading it seems hopelessly dull. Even the exquisite illustrations, which are so well chosen and so well presented, do not quite offset the numerous pages of quota- tions from the Greek authors, which are under- stood by most readers only by reference to the accompanying English translation. However, it will bear re-reading more than once. The diction is clear and well chosen, equal to the illustrations, but it is, after all, a pretty stiff dose of erudition mingled with a great many reflections on archi- tecture as set forth in the old dramatic poets. Daedalus and Thespis: The Construction of the Ancient Dramatic Poets to Our Knowledge of the Arts and Crafts OF Greece, by Walter Miller, of the Universitygof Missouri. Vol. I, “Architecture and Topography.” New York: The Macmillan Company, 329 pages, 48 illus- trations, size 8 x 11. $6.50. THE AMERICAN ARCHITECT
Page 67
A CONDOS АЭСЬЛӘСРУАЭСЬ SOLON SEDGWICK DUMB WAITERS and ELEVATORS Jor all purposes Sidewalk Elevator at Left Geared Automatic Brake Dumb Waiter Type "FDCG" ще construction necessitates the most improved and eco- nomical equipment of every kind. Most architects are well acquainted with the advantages of Sedgwick Dumb Waiters and Elevators. Early Consultation Advisable Blue prints and detailed specifications covering the exact equipment best тиран. со your ге- quirements will be gladly furnished upon request. If our A. I. A. Catalog is not in your files, write for it today. REPRESENTATIVES IN MANY CITIES A| SEDGWICK MACHINE WORKS 159 West 15th Street New York Under Counter Dumb Waiter Freight Elevator SEDGWICK SERVICE SATISFIES M OO NEXSMEXSSNEXS ОС) NOOO NOE NON, FOR SEPTEMBER 1929 13
Page 68
CHURCH BUILDING COMPETITION HE Christian Herald Bureau of Church Plan- ning has announced its second annual Church Building Competition. This competition is for Protestant churches, seating from 150 to 600 persons, that have already been built. There are three cash prizes to be awarded and divided be- tween the architects and the churches. The jury of awards will consist of Harry Wiley Corbett, Hubert Frohman and Elmo Cameron Lowe. R. H. Blatter, consulting architect of the Bureau, will act as professional advisor. The competition calls for photographs and plans of churches com- pleted since July 1st, 1927. Entries must be made on or before November 15th, 1929. The com- petition rules may be obtained by addressing the Bureau of Church Planning, Christian Herald Association, Inc., 419 Fourth Avenue, New York City. oln PHILADELPHIA ARCHITECTS TO HOLD EXHIBITION HE American Institute of Architects, Phila- delphia Chapter, and the T-Sguare Club of that city, will hold their Thirty-second Annual Architectural Exhibition from November Ist to the 15th, inclusive. The Joint Exhibition Board of the affiliated organization has announced that the exhibition will be held this year through the courtesy of John Wanamaker of Philadelphia in the art galleries of that store. The Joint Exhibition Board in charge of this year's display is Nicola D'Ascenzo, Chairman; Howard L. Shay, Vice-Chairman; George Whar- ton Pepper, Jr., Secretary; James Bush-Brown, Treasurer; D. Knickerbacker Boyd, Managing Director: Herbert R. Leicht, Harry Sternfeld, and Isabel W. McCoy, Executive Secretary of the Philadelphia Chapter, A. І. А. A Circular of Information is now available which, together with entry slips and labels, may be had upon application to the Executive Secretary, 112 South 16th Street, Philadelphia, Pa. Photographs for the Year Book illustrations and return of entry slips must be received by the Executive Secretary before Tuesday, September 10th. Exhibits will be received from October 21st to October 23rd, and they will be discharged on the 16th of November, 1929. 14 PRIZE WINNERS IN 1929 NATIONAL BETTER HOMES COMPETITION ANNOUNCED ESIGNS submitted in the National Better Homes Competition, conducted by the Home Owners’ Service Institute, were recently judged and resulted in the first grand prize being awarded to H. Roy Kelly of Los Angeles. Harrison Clarke of Los Angeles received the second grand prize, and Amadeo Leone was awarded the third grand prize. In addition to the national or grand prizes, the competition included regional prizes for thir- teen sections of the United States. The regional judgments replaced the customary preliminary competition in arriving at the national awards. The total value of all prizes awarded was $29,000. The national awards were $5,000, $3,000 and $1,500. К CHICAGO WAR MEMORIAL T HE War Memorial Committee of the City of Chicago announces, to all architects residing in the United States, that a nation-wide compe- tition will be held for the Chicago War Mem- orial with prizes and in accordance with compe- tition rules of the American Institute of Archi- tects. Programs will be issued September Ist and judgment announced early in December. Under this general invitation programs may be obtained up to October lst by qualified applicants from Earl H. Reed, Jr., Advisor, War Memorial Com- petition, 435 North Michigan Avenue, Chicago, Illinois. E PERSONALS Randolph Frantz, architect, of 376 Walnut Avenue, S. W., Roanoke, Va., writes that he would like to receive manufacturers’ samples agd catalogues. oln Hoit, Price % Barnes, architects, announce the removal of their offices to 2500 Telephone Build- ing, Kansas City, Mo. ote Margon % Holder, architects, announce the re- moval of their office to 18 East 41st Street, New York City, from 29 West 57th Street, New York. THE AMERICAN ARCHITECT