5.6: Exercise- The Average Reference

Applied Event-Related Potential Data Analysis 2e · LibreTexts

0%

Contents

    Text

    Size
    100%
    Theme
    Typeface
    Line length
    Spacing

    Read aloud

    How

    Speed: 1×
    Light up
    Highlight

    Symbols: Mulberry Symbols, © 2018–2026 Steve Lee, CC BY-SA 4.0 (licence, the set), the site's own copies.

    From LibreTexts, under CC BY-NC 4.0, as the source states it; its equations are written in TeX, which the PDF shows typeset. This page at LibreTexts.

    5.6: Exercise- The Average Reference

    Earlier in this chapter, we defined the absolute voltage as the potential between a given electrode and the average of the entire surface of the head. This is a strictly theoretical concept, because we can’t record from the entire surface of the head. How would you get an electrode on the bottom side of someone’s skull?

    However, many researchers try to approximate the absolute voltage by using the average across all the electrode sites in their recording as the reference. Although this has been shown to be a good approximation for one particular generator site when an extremely broad array of electrodes is used (Dien, 1998), it often provides a very poor approximation of the absolute voltage (see Chapter 7 in Luck, 2014). Nonetheless, the average reference can still be useful under some conditions. For example, it is commonly used for studies of face-elicited N170 activity (Rossion & Jacques, 2012), and we used it for the N170 paradigm in the ERP CORE (Kappenman et al., 2021).

    In this exercise, we’ll re-reference the data in Grand_N400_diff.erp to the average of all the EEG electrodes. To accomplish this, load Grand_N400_diff.erp into eStudio if it’s not already loaded, and make sure that the original version of this ERPset is selected in the ERPsets panel (rather than the ERPsets that you created with Cz or Oz as the reference). Go to the Channel Operations panel and click the Clear button to clear out any equations that remain in the text box from the last time you used this routine, and make sure that the Mode is set to Create new ERPset.

    Now click the Reference Asst button. In the text box labeled Ch_REF near the top of the window, type avgchan(1:28). This indicates that you want to use the average of channels 1–28 as the reference. We’re excluding channels 29 and 30, which are the EOG channels. As before, select Exclude these channels with 29 30 in the text box. Then click OK. You’ll see that the list of equations in the Channel Operations panel subtracts avgchan(1:28) from each individual channel, except for the EOG channels. If you go through the algebra of this subtraction, you’ll see that this will create EEG channels that are equal to the active electrode minus the average of all the electrodes. Now click Run and name the new ERPset Grand_N400_diff_AvgRef.

    If you look at the waveforms for Bins 3-5, you’ll see that the difference between related and unrelated targets with the average reference is positive at some sites and negative at others. This is an inevitable consequence of using the average of all sites as the reference. That is, at every moment in time, the average-referenced voltages across the different electrode sites must sum to zero, so the voltage will be negative at some electrode sites and positive at others. This is easier to see with a butterfly plot, in which we overlay the waveforms for all the channels. To make a butterfly plot, go to the Plot Settings panel and change the pop-up menu in the middle from CHANNELS with BINS overlay to BINS with CHANNELS overlay (see Screenshot 5.3). Now, each individual panel of the plot shows one bin, with all the channels overlaid. The result often looks like a butterfly (although the example shown in Screenshot 5.3 does not).

    Butterfly Plot

    Screenshot 5.3

    In the butterfly plot, you can see that the voltage at any given time point is positive at some electrode sites and negative at others. And if you summed together all the channels for a given bin, you would get a value of zero at every time point. This is true both for parent waveforms (e.g., the waveforms for the related and unrelated target words) and for difference waveforms. If you select Grand_N400_diff in the ERPsets panel to see the butterfly plot with the original reference (the average of P9 and P10), you'll see that it is no longer the case that the channels all sum to zero at each time point. For example, almost all of the channels are negative during the N400 period in the difference wave. It's only when you use the average of all sites as the reference that you necessarily have equal amounts of positive and negative at a given time point.

    So, when you use the average reference, don’t think you’ve discovered something interesting when you find that your experimental effect is positive in some channels and negative in others. It’s just a necessary consequence of the algebra. Some components and experimental effects will exhibit such polarity inversions with other references, but it is inevitable with the average reference.

    Heads are not actually spheres

    Using the average across sites as the reference in order to approximate the absolute voltage assumes that the surface of the head sums to zero, but this is only true for spheres. I have yet to meet someone with a spherical head. And no neck. Fortunately, there is a way to estimate the true zero, called the Reference Electrode Standardization Technique (REST), and there is an EEGLAB plugin that implements it (Dong et al., 2017). To use it, you'll need to launch the EEGLAB GUI instead of the eStudio GUI. But after you've applied this reference and saved the resulting EEGset, you can open the EEGset in eStudio for any further processing.

     


    This page titled 5.6: Exercise- The Average Reference was last modified on Thu, 01 Oct 2026 18:52:31 GMT and is shared under a CC BY-NC 4.0 license and was authored, remixed, and/or curated by Steven J Luck directly on the LibreTexts platform.