    The methods thus far discussed are limited in how closely we can see the components of the nervous system. For example, it could be useful to try and see the specific cellular features of a healthy neuron and compare that with the features of a neuron that has been damaged by multiple sclerosis. To be able to visualize the morphology of structures smaller than hundreds of microns, you’ll need a different set of techniques.

    6.3.1 Microscopy

    Example questions answered:

    “What is the diameter of the soma of a granule cell?”

    “How are the retinal neurons at the fovea different from the neurons in the periphery?”

    Among the techniques described in this chapter, short of physical dissection or autopsy, microscopy may be the oldest. Microscopy began with the Dutch scientist Antonie van Leeweunhoek in the late 1700s. Originally, microscopy was more of a novelty for entertainment rather than a piece of equipment fit for a laboratory. Using a series of precisely-crafted lenses and a bright source of light, Leeweunhoek was able to see tiny animals living in water.

    Microscopy gives us the ability to see things at a level of resolution that would otherwise not be possible. Compared to today’s microscopes, the earliest scopes provided poor magnification, able to bring us only about 40 times closer than the unaided eye (these days, a standard laboratory microscope provides a level of magnification up to 400 or 1,000 times closer). Other types of microscopes, such as the electron microscopes developed in the 1930s, use an electron emission device in conjunction with high speed detectors to visualize structures that are on the order of nanometers, giving us a zoom of up to a million times!

    A different form of microscopy relies on the fluorescent properties of molecules such as green fluorescent protein (GFP). Fluorescence microscopes use light sources such as filtered light or lasers which emit light at specific wavelengths. Photons at specific wavelengths activate the proteins, which in turn emit light at a different wavelength. The emission of this second color of light can then be detected.

    Illustration
    Figure 6.18 The fluorescence microscope (diagram, top) can be used to excite GFP (green) expressed in hippocampal neurons (bottom).

    Microscopy is a standard part of a neuroscience research kit. Most of the techniques below will rely on microscopy to visualize some component of the nervous system.

    6.3.2 Staining

    Example questions answered:

    “Where is the white matter located in the brain stem?”

    “What is the morphology of dendritic arbor of a cerebellar Purkinje cell?”

    Staining is an imaging method that is often used in conjunction with microscopy. Thin slices of brain tissue are exposed to various chemical processes. The chemicals that are used for staining have different affinities for parts of cells. For example, there are stains that specifically stain myelin (Luxol Fast Blue), some that only stain neurons (cresyl violet), and some that stain only the genetic material found in cell nuclei (DAPI).

    One of the most influential biological stains was developed in the late 1800s by the Italian anatomist Camillo Golgi. The Golgi stain is a silver-based stain that filled every single part of the neuron, from the dendrites to the axons, turning the cells black. The stain is only taken up by less than 1% of neurons, and because of the low rate of staining, individual neurons could be traced in their entirety and drawn. This stain led to a contentious battle between Golgi and a rival neuroanatomist Santiago Ramon y Cajal over the nature of the connections between neurons.

    Illustration
    Figure 6.19 A slice of cerebellum, with the myelin stained with Luxol Fast Blue and the neurons stained with cresyl violet (top; 100x magnified). A pyramidal cell treated with a Golgi stain (bottom).

    For staining to work, the tissue needs to be subjected to a series of chemical processes. First, the tissue needs to be fixed. Fixation is a chemical process that is accomplished by exposing the tissue to a chemical like paraformaldehyde (PFA). The most effective way to expose every part of the body to fixative is to “hijack” the endogenous circulatory system by flushing fixative through the arteries, a process called perfusion. Chemically, fixatives cause adjacent proteins to become covalently bonded (crosslinked), a process which causes the proteins to become unchangeable - they become “fixed” in time. These fixatives are very harsh chemicals, and usually kill microorganisms and inactivate the endogenous enzymes that normally degrade biological tissue. (As a side note, fixatives are particularly nasty carcinogens that can permeate easily through latex gloves.)

    Illustration
    Figure 6.20 A chemical fixative such as PFA creates covalent bonds between lysine (blue) amino acid residues of proteins.

    After fixation, devices such as a microtome or cryostat are used to slice the brain into sections as thin as 10 microns. Stains do not always reliably pass all the way through thick sections of tissue such as an intact brain. With thin slices, chemical stains are able to permeate through the depth of the tissue.

    Illustration
    Figure 6.21 A microtome (left) or a cryostat (right) are devices for taking brain sections. The microtome fits on a tabletop, and cuts accurately down to 100 uM thin. The cryostat is larger, and can cut 10 uM thin slices.

    Certain staining methods can also be used to determine projections of neurons. These techniques are collectively called tract tracing methods. An anterograde trace stains cells from the soma to the axon terminal, while a retrograde trace is taken up by the axon terminals and stains the soma. These strategies are helpful for visualizing the nature of connectivity in the nervous system.

    Staining cannot be done on living tissue; it can only work on fixed tissue.

    Illustration
    Figure 6.22 In tract tracing, injection of different staining dyes can help us identify the connectivity of neurons. If an injection site contains somata, the dye is transported in an anterograde direction towards the area where the axon terminals are located (green). If the injection site contains axon terminals, the dye is taken up and transported in a retrograde direction towards the cell bodies (red).

    6.3.3 Immunohistochemistry staining

    Example questions answered:

    “Where is the protein actin located in a neuron?”

    “Is the protein PSD-95 expressed in the same areas as the NMDA receptor protein?”

    Immunohistochemistry (IHC) is a modification of the staining methods that gives increased specificity over the other chemical stain methods presented above. IHC is used because it is good for identifying the location of specific proteins at a subcellular level. In other words, you can use IHC to figure out where specific proteins are located inside or on the cell.

    Illustration
    Figure 6.23 At low magnification (top), immunohistochemistry in conjunction with fluorescence microscopy can help us identify the morphology and location of different populations of cells. At high magnification (bottom), we can identify the location of different proteins within a cell, such as tubulin (green), which makes up the microtubules.

    As with other staining methods, IHC begins with thinly prepared sections of fixed tissue. Instead of exposing the tissue to various chemical stains, IHC utilizes the molecular properties of antibodies, proteins that function in the immune response. Each antibody has a part of their Y-shaped structure that is able to bind to other targets (which are called antigens) with extremely high specificity. This other target could be a specific protein, such as serotonin receptors or amyloid precursor protein, or an enzyme such as choline acetyltransferase. Antibodies are created with a particular target in mind, so when the antibody is bathed over the brain tissue, the antibody will adhere only to that target.

    The IHC protocol often uses two different antibodies. The first antibody, called the primary antibody, is selected because of its ability to bind to the antigen that you are interested in studying. For example, if you wanted to search for the location of a protein called NeuN, the primary antibody would be anti-NeuN. Afterwards, the tissue will be exposed to the secondary antibody.

    Illustration
    Figure 6.24 The primary antibody (purple) is chosen because it binds to a specific protein of interest (magenta). In a second step, the secondary antibody (light blue), conjugated with a fluorophore (in this case GFP), binds to the primary antibody.

    This second antibody is chosen because its target is something that is found on the primary antibody. As an additional feature, the secondary antibody is conjugated with a light sensitive fluorophore, or light-producing molecule. Activation of this fluorophore on the secondary antibody under fluorescence microscopy is then used to identify the location of the primary antibody.

    It is also possible to use antibodies and fluorescence microscopy to visualize the elements of cells in a culture dish (in vitro). The theory behind this technique is the same as in IHC, but the name is different. Instead, this approach is called immunocytochemistry (cyto = cell, while histo = tissue). This immunolabeling strategy can also be applied to a whole brain after it has been made transparent through CLARITY (section 6.1.3).

    One of the main difficulties with immunochemistry is that the antibodies often exhibit nonspecific binding. Although antibodies are used because of their ability to recognize and differentiate between similar-looking antigens, often they bind to the wrong targets. When they do, it creates a false positive, causing a fluorescent signal to appear when there is actually no protein present. Nonspecific binding also causes an increase in background noise, making it more difficult to identify a genuine fluorescent signal, indicating presence of the protein of interest. Various steps can be taken during the immunochemistry procedure that minimize the likelihood of nonspecific binding, such as thorough rinsing and exposure to blocking agents.

    For an immunochemistry protocol to work, an antibody must exist for the specific target of interest. However, an antibody has not been developed against every single protein or enzyme. Another issue is that some proteins are structurally very similar to other proteins, and an antibody has not yet been developed that can differentiate the two. For example, the structure of the dopamine receptor type 2 is so similar to type 3, that there are no antibodies that can target one without the other.


    This page titled 6.4: Imaging the cells of the nervous system was last modified on Wed, 08 Jul 2026 03:46:42 GMT and is shared under a CC BY-NC 4.0 license and was authored, remixed, and/or curated by Austin Lim via source content that was edited to the style and standards of the LibreTexts platform.