    2.1: Identification of an Unknown - Experiment
    SAFETY PRECAUTIONS

    1. Wear chemical splash goggles throughout the experiment.

    2. Gloves are provided if you wish to wear them.

    3. Work with all chemicals under the fume hood.

    4. Be careful when handling hot glassware.

    5. Dispose of all waste in the appropriate waste containers.

    6. Clean your work area (hood and lab bench) and return all glassware and equipment to the appropriate place once you finish the experiment.

    7. Always wash your hands immediately upon leaving the lab.

    EQUIPMENT AND CHEMICALS NEEDED

    Table \(\PageIndex{1}\): Materials Needed
    Equipment Chemicals
    Medium Size Test Tube Unknown
    Glass Stirring rod Deionized water
    10.0 mL graduated cylinder Non-halogenated organic waste container
    Simple Distillation Apparatus  
    Milligram balance  

    EXPERIMENTAL PROCEDURE

    PART I: SOLUBILITY OF THE UNKNOWN

    1. Add 1.0 mL of water and 1.0 mL of the unknown to a medium-sized test tube. Stir the liquids to determine whether or not a solution forms.

    2. Record your observations in the data and observations section.

    3. Pour the contents of the test tube into the non-halogenated organic waste container. Clean the test tube with soap and water, and return it to its appropriate place.

    PART II: DETERMINATION OF THE DENSITY OF THE UNKNOWN

    1. Weigh an empty 10.0 mL graduated cylinder. Record the value under trials 1-3 in the data table.

    2. Add anywhere between 1.0 and 10.0 mL of the unknown to the graduated cylinder. Record the exact volume used under trial 1 in the data table.

    3. Obtain the combined mass of the graduated cylinder and the unknown liquid. Record the exact value under trial 1 in the data table.

    4. Find the mass of the unknown liquid, and then calculate its density. Record this information under trial 1 in the data table.

    5. Pour the contents of the graduated cylinder into the non-halogenated organic waste container.

    6. Repeat steps 2-4 for trials 2 and 3, using a different volume of the unknown each time.

    7. Calculate the average density of the unknown liquid.

    PART III: DETERMINATION OF THE BOILING POINT OF THE UNKNOWN

    1. Set up a simple distillation apparatus under the hood, and determine the boiling point of 10.0 mL of the unknown liquid. Your instructor will demonstrate the setup based on the equipment and conditions for your lab.

    2. Once approximately 2.0 mL of liquid remains in the distilling flask, turn off the heat but leave the water running.

    3. Once the glassware is cool, disassemble the apparatus, clean all glassware, and pour the unknown liquid into the non-halogenated waste container.

    PART IV: IDENTIFICATION OF THE UNKNOWN LIQUID

    Using the results of the solubility test, density, and boiling point, identify the unknown liquid from the list of known solutions listed in pre-lab question 3.


    This page titled 2.1: Identification of an Unknown - Experiment was last modified on Fri, 16 Jan 2026 03:56:38 GMT and is shared under a CC BY 4.0 license and was authored, remixed, and/or curated by Saadia Khan.