Opening the book…
- Chemical splash goggles and laboratory coats must be worn at all times.
- Sodium hydroxide (NaOH), hydrochloric acid (HCl), and glacial acetic acid solutions are CORROSIVE and CAUSTIC. Avoid skin and eye contact. Flush spills immediately with copious water.
EQUIPMENT AND CHEMICALS NEEDED
| Equipment & Hardware | Chemicals & Solutions |
|---|---|
| 50-mL burets (2), buret clamp, & ring stand | Sodium acetate anhydrous, NaC2H3O2(s) |
| Vernier pH Sensor & LabQuest interface | 0.1 M Acetic acid, HC2H3O2(aq) |
| Magnetic stirrer & magnetic stir bar | 1.0 M Acetic acid, HC2H3O2(aq) |
| Electronic balance (±0.001 g) | 0.5 M Sodium hydroxide, NaOH(aq) titrant |
| 50-mL graduated cylinder & 150-mL beakers (2) | 0.5 M Hydrochloric acid, HCl(aq) titrant |
| Utility clamp & wash bottle with distilled water | pH 4.00 Buffer calibration solution |
EXPERIMENTAL PROCEDURE
Part A: Prepare and Test Buffer Solution A
- Use your Pre-Lab calculations to prepare 50.0 mL of Buffer A. Weigh the calculated mass of solid sodium acetate (NaC2H3O2) on an electronic balance. Dissolve it in exactly 50.0 mL of 0.1 M acetic acid solution using a graduated cylinder and stir thoroughly.
- Set up two 50-mL burets on a buret clamp and ring stand (Figure \(\PageIndex{1}\)). Rinse and fill Buret 1 with 0.5 M NaOH solution. Rinse and fill Buret 2 with 0.5 M HCl solution. Record initial buret volumes.
Figure \(\PageIndex{1}\): Buffer titration experimental apparatus setup. - Measure 10.0 mL of Buffer A into a 150-mL beaker and add 15 mL of distilled water. Place the beaker on a magnetic stirrer beneath the NaOH buret and add a stir bar.
- Rinse the pH sensor with distilled water. Check calibration in pH 4.00 buffer.
1. Calibration Check
- Submerge probe in pH 4.00 buffer. If reading is between 3.90 and 4.10, proceed. Otherwise, recalibrate using pH 4.00 and pH 7.00 standards.
2. Data Collection Mode
- Set Mode to Events with Entry.
- Set Column Name to "Volume Added" and Units to "mL".
- Tap Collect. Tap Keep after each titrant addition, typing in cumulative added volume (0.0, 0.5, 1.0, 1.5...).
- Base Titration of Buffer A:
- Record initial buret reading and initial pH of Buffer A before adding base.
- Add 0.50 M NaOH in small increments (0.50 mL). After each addition, allow pH to stabilize, then record buret reading and pH.
- Continue adding NaOH until the solution pH increases by precisely 2.00 pH units above the initial buffer pH.
- Once pH has increased by 2 units, continue adding 0.50 M NaOH in 0.50-mL increments past the endpoint until a sharp pH rise is observed.
- Acid Titration of Buffer A:
- Transfer a fresh 10.0-mL sample of Buffer A into a clean 150-mL beaker and add 15 mL of distilled water.
- Position beaker under Buret 2 (0.5 M HCl). Record initial pH and initial buret reading.
- Add 0.50 M HCl in 0.50-mL increments until the solution pH decreases by precisely 2.00 pH units below initial buffer pH. Record all buret readings and pH values in Data Table 1.
Part B: Prepare and Test Buffer Solution B
- Use your Pre-Lab calculations to prepare 50.0 mL of Buffer B. Weigh the calculated mass of solid sodium acetate (NaC2H3O2) and dissolve it in 50.0 mL of 1.0 M acetic acid solution. Refill burets with 0.5 M NaOH and 0.5 M HCl if needed.
- Measure 10.0 mL of Buffer B into a 150-mL beaker and add 15 mL of distilled water. Repeat the base titration (NaOH) and acid titration (HCl) procedures from Part A, testing until pH changes by ±2.00 units. Record all data.
Immediately compare Buffer A and Buffer B capacity data:
- Buffer B (1.0 M acid system) should require significantly greater titrant volume of NaOH or HCl to shift pH by 2 units compared to Buffer A (0.1 M acid system).
- Quality Check: If Buffer B resists pH change no better than Buffer A, re-verify stock acid bottle concentrations. You may have accidentally used 0.1 M acid for both buffers.
- Dispose of all titrated buffer mixtures in the designated AQUEOUS ACID-BASE WASTE container.
- Rinse the pH sensor with distilled water and store in electrode storage solution. Clean all glassware.
This page titled 5.1: Investigating Buffers - Experiment was last modified on Tue, 06 Oct 2026 22:39:27 GMT and is shared under a CC BY 4.0 license and was authored, remixed, and/or curated by Vince Hradil.