5.1: Investigating Buffers - Experiment

General Chemistry II Lab Manual · LibreTexts

0%

Contents

    Text

    Size
    100%
    Theme
    Typeface
    Line length
    Spacing

    Read aloud

    How

    Speed: 1×
    Light up
    Highlight

    Symbols: Mulberry Symbols, © 2018–2026 Steve Lee, CC BY-SA 4.0 (licence, the set), the site's own copies.

    From LibreTexts, under CC BY 4.0, as the source states it; its equations are written in TeX, which the PDF shows typeset. This page at LibreTexts.

    5.1: Investigating Buffers - Experiment
    SAFETY PRECAUTIONS
    • Chemical splash goggles and laboratory coats must be worn at all times.
    • Sodium hydroxide (NaOH), hydrochloric acid (HCl), and glacial acetic acid solutions are CORROSIVE and CAUSTIC. Avoid skin and eye contact. Flush spills immediately with copious water.

    EQUIPMENT AND CHEMICALS NEEDED

    Table \(\PageIndex{1}\): Materials Needed
    Equipment & Hardware Chemicals & Solutions
    50-mL burets (2), buret clamp, & ring stand Sodium acetate anhydrous, NaC2H3O2(s)
    Vernier pH Sensor & LabQuest interface 0.1 M Acetic acid, HC2H3O2(aq)
    Magnetic stirrer & magnetic stir bar 1.0 M Acetic acid, HC2H3O2(aq)
    Electronic balance (±0.001 g) 0.5 M Sodium hydroxide, NaOH(aq) titrant
    50-mL graduated cylinder & 150-mL beakers (2) 0.5 M Hydrochloric acid, HCl(aq) titrant
    Utility clamp & wash bottle with distilled water pH 4.00 Buffer calibration solution

    EXPERIMENTAL PROCEDURE

    Part A: Prepare and Test Buffer Solution A

    1. Use your Pre-Lab calculations to prepare 50.0 mL of Buffer A. Weigh the calculated mass of solid sodium acetate (NaC2H3O2) on an electronic balance. Dissolve it in exactly 50.0 mL of 0.1 M acetic acid solution using a graduated cylinder and stir thoroughly.
    2. Set up two 50-mL burets on a buret clamp and ring stand (Figure \(\PageIndex{1}\)). Rinse and fill Buret 1 with 0.5 M NaOH solution. Rinse and fill Buret 2 with 0.5 M HCl solution. Record initial buret volumes.
      Dual buret titration apparatus for testing buffer capacity with acid and base
      Figure \(\PageIndex{1}\): Buffer titration experimental apparatus setup.
    3. Measure 10.0 mL of Buffer A into a 150-mL beaker and add 15 mL of distilled water. Place the beaker on a magnetic stirrer beneath the NaOH buret and add a stir bar.
    4. Rinse the pH sensor with distilled water. Check calibration in pH 4.00 buffer.
      VERNIER TECH BOX: BUFFER TESTING

      1. Calibration Check

      • Submerge probe in pH 4.00 buffer. If reading is between 3.90 and 4.10, proceed. Otherwise, recalibrate using pH 4.00 and pH 7.00 standards.

      2. Data Collection Mode

      • Set Mode to Events with Entry.
      • Set Column Name to "Volume Added" and Units to "mL".
      • Tap Collect. Tap Keep after each titrant addition, typing in cumulative added volume (0.0, 0.5, 1.0, 1.5...).
    5. Base Titration of Buffer A:
      1. Record initial buret reading and initial pH of Buffer A before adding base.
      2. Add 0.50 M NaOH in small increments (0.50 mL). After each addition, allow pH to stabilize, then record buret reading and pH.
      3. Continue adding NaOH until the solution pH increases by precisely 2.00 pH units above the initial buffer pH.
      4. Once pH has increased by 2 units, continue adding 0.50 M NaOH in 0.50-mL increments past the endpoint until a sharp pH rise is observed.
    6. Acid Titration of Buffer A:
      1. Transfer a fresh 10.0-mL sample of Buffer A into a clean 150-mL beaker and add 15 mL of distilled water.
      2. Position beaker under Buret 2 (0.5 M HCl). Record initial pH and initial buret reading.
      3. Add 0.50 M HCl in 0.50-mL increments until the solution pH decreases by precisely 2.00 pH units below initial buffer pH. Record all buret readings and pH values in Data Table 1.

    Part B: Prepare and Test Buffer Solution B

    1. Use your Pre-Lab calculations to prepare 50.0 mL of Buffer B. Weigh the calculated mass of solid sodium acetate (NaC2H3O2) and dissolve it in 50.0 mL of 1.0 M acetic acid solution. Refill burets with 0.5 M NaOH and 0.5 M HCl if needed.
    2. Measure 10.0 mL of Buffer B into a 150-mL beaker and add 15 mL of distilled water. Repeat the base titration (NaOH) and acid titration (HCl) procedures from Part A, testing until pH changes by ±2.00 units. Record all data.
      DATA SKILL: CAPACITY CHECK

      Immediately compare Buffer A and Buffer B capacity data:

      • Buffer B (1.0 M acid system) should require significantly greater titrant volume of NaOH or HCl to shift pH by 2 units compared to Buffer A (0.1 M acid system).
      • Quality Check: If Buffer B resists pH change no better than Buffer A, re-verify stock acid bottle concentrations. You may have accidentally used 0.1 M acid for both buffers.
    CHEMICAL DISPOSAL
    • Dispose of all titrated buffer mixtures in the designated AQUEOUS ACID-BASE WASTE container.
    • Rinse the pH sensor with distilled water and store in electrode storage solution. Clean all glassware.

    This page titled 5.1: Investigating Buffers - Experiment was last modified on Tue, 06 Oct 2026 22:39:27 GMT and is shared under a CC BY 4.0 license and was authored, remixed, and/or curated by Vince Hradil.