13.5: Cell Number, Viability, and Cytotoxicity

Cell Culture Textbook (Biot 77 IVC) · LibreTexts

0%

Contents

    Text

    Size
    100%
    Theme
    Typeface
    Line length
    Spacing

    Read aloud

    How

    Speed: 1×
    Light up
    Highlight

    Symbols: Mulberry Symbols, © 2018–2026 Steve Lee, CC BY-SA 4.0 (licence, the set), the site's own copies.

    From LibreTexts, under CC BY-NC-SA 4.0, as the source states it; its equations are written in TeX, which the PDF shows typeset. This page at LibreTexts.

    13.5: Cell Number, Viability, and Cytotoxicity

    Cytotoxicity is a harmful effect that causes cell injury or death. Cytostasis is reduced cell proliferation without necessarily causing cell death. A treated well can contain fewer cells than its control because cells divided more slowly. The difference is biologically meaningful, but calling it cell killing requires additional evidence.

    Viability describes whether cells are alive according to a stated measurement. Dye exclusion tests membrane integrity. Metabolic assays estimate cell health through biochemical activity. Clonogenic survival asks whether cells retain the ability to produce colonies. These methods examine different properties and can disagree without any measurement being automatically wrong.

    For example, suppose two groups each begin with 20,000 cells. The control reaches 80,000 cells and the treatment reaches 40,000 cells. If both groups remain mostly dye-excluding, the treatment has half as many endpoint cells but has still doubled from its starting number. “The treatment killed half the cells” is not supported by that observation. A time-zero reference helps distinguish reduced accumulation from a decrease below the starting population.

    Measurement

    Main property measured

    Interpretation limit

    Direct cell count

    Number of recovered or imaged cells

    Requires a separate way to identify viable cells

    Dye exclusion

    Membrane integrity

    Does not test long-term reproduction

    ATP or reagent conversion

    Biochemical activity in the sample

    Activity per cell and interference can change

    Colony formation

    Capacity to form qualifying colonies

    Depends on plating and growth conditions

    Scratch closure

    Change in cell-free gap

    Movement, division, and loss can all contribute

    ATP assays produce light related to the ATP in a sample. Under validated conditions, this signal can estimate metabolically active cell abundance. However, ATP per cell can change without the same change in live-cell count. Common endpoint ATP assays break open cells. Plan separate wells if later growth or microscopy will also be measured.

    Tetrazolium assays, such as MTT or MTS, and resazurin assays rely on biochemical conversion of an assay reagent. Metabolic state, incubation time, and assay conditions affect the response. Verify the useful signal range for the chosen cell density. A saturated reading cannot distinguish two different cell populations.

    An orthogonal assay uses a different measurement principle to examine the same general question. For example, membrane-integrity staining and a cell count can help interpret a reduced ATP result. Agreement across different methods makes the interpretation stronger; disagreement identifies a question that needs investigation.

    An assay interference effect occurs when the treatment changes the measurement process rather than the intended biological endpoint. Colored compounds can affect absorbance, fluorescent compounds can affect fluorescence, and treatments can alter reagent chemistry. A no-cell compound control can reveal some interference. Other effects require additional checks, such as adding compound to a defined assay standard.


    This page titled 13.5: Cell Number, Viability, and Cytotoxicity was last modified on Wed, 21 Oct 2026 01:36:15 GMT and is shared under a CC BY-NC-SA 4.0 license and was authored, remixed, and/or curated by Emalee MacKenzie.