Opening the book…
Use the final culture volume when calculating exposure. The volume of the complex preparation
is only one part of that volume. Keep mass-based amounts, such as micrograms of DNA, separate from molar concentrations, such as nanomolar siRNA.
Stock volume needed = required amount ÷ stock concentration
For molar dilution: C₁ × V₁ = C₂ × V₂
Here C₁ and V₁ describe the stock concentration and stock volume; C₂ and V₂ describe the desired final concentration and final volume. Use compatible units. One micromolar equals 1,000 nanomolar, and one milliliter equals 1,000 microliters.
A useful relationship for small RNA calculations is: 1 nM × 1 mL = 1 pmol. A picomole is an amount of substance; nanomolar is an amount per volume. The same number of picomoles gives a different concentration when the final well volume changes.
Worked Example 12.1 Calculating an siRNA Addition
A hypothetical plan calls for a final siRNA concentration of 20 nM in a final well volume of 2.0 mL. The stock is 10 µM. These are calculation values, not recommended treatment settings.
Required amount = 20 nM × 2.0 mL = 40 pmol
Stock concentration = 10 µM = 10 pmol/µL
Stock volume = 40 pmol ÷ 10 pmol/µL = 4.0 µL
The final 2.0 mL includes the added complex mixture. If 0.2 mL of complexes is added to an existing 2.0 mL culture without removing liquid, the final volume is 2.2 mL. The same 40 pmol then gives 40 ÷ 2.2 = 18.2 nM. Record the actual volume rather than reporting the planned concentration automatically.
If the calculated transfer is too small for the available pipette, an approved working dilution may improve measurement. Calculate and record the new stock concentration. Changing stock dilution does not change the intended final amount if the correct amount is delivered.
Worked Example 12.2 Preparing an mRNA Batch
A hypothetical treatment requires 1.0 µg mRNA per well for four wells. The preparation plan includes a 10% allowance for liquid retained in tubes and tips. The mRNA stock is 0.20 µg/µL.
Preparation equivalents = 4 wells × 1.10 = 4.4 well-equivalents
mRNA needed = 4.4 × 1.0 µg = 4.4 µg
Stock volume = 4.4 µg ÷ 0.20 µg/µL = 22 µL
Scale the other mixture components according to the evaluated formulation, and dispense the specified amount to each well. The allowance remains extra mixture; it is not extra dose for every well. Prepare the control mRNA separately with its own matched calculations.
If the plan instead uses plasmid DNA, the same amount-divided-by-concentration arithmetic applies when both values use mass units. Equal masses of different-length nucleic acids do not necessarily contain equal numbers of molecules. Record whether matching is based on mass, molarity, or another defined property.
Attribution: Images AI-generated using ChatGPT Modified by Emalee Mackenzie, Irvine Valley College. Licensed under CC BY-NC-SA
This page titled 12.8: Calculating Cargo Amount and Final Concentration was last modified on Wed, 21 Oct 2026 01:36:03 GMT and is shared under a CC BY-NC-SA 4.0 license and was authored, remixed, and/or curated by Emalee MacKenzie.