The following example illustrates dilution arithmetic. It is not a universal culture 
prescription. Suppose the measured source concentration is 0.80 × 10⁶ viable cells/mL. The selected starting target is 0.20 × 10⁶ viable cells/mL in a final volume of 20.0 mL.
Use C₁V₁ = C₂V₂, where C₁ is source concentration, V₁ is source volume transferred, C₂ is the target concentration, and V₂ is the final culture volume.
V₁ = C₂ × V₂ ÷ C₁ = (0.20 × 10⁶ cells/mL × 20.0 mL) ÷ (0.80 × 10⁶ cells/mL) = 5.0 mL.
Fresh-medium volume = 20.0 mL − 5.0 mL = 15.0 mL.
The transferred population is 0.80 × 10⁶ cells/mL × 5.0 mL = 4.0 × 10⁶ viable cells. Dividing that number by 20.0 mL confirms the intended starting concentration. Check that 5.0 mL of well-mixed source culture remains available after sampling.
Now consider a transfer error. If 6.0 mL of source culture is added to the planned 15.0 mL of medium, the final volume is 21.0 mL, not 20.0 mL. The estimated starting concentration becomes (0.80 × 10⁶ × 6.0) ÷ 21.0 = about 0.229 × 10⁶ viable cells/mL. Record actual volumes and calculate from what happened. Do not silently enter the planned density as the actual one.
A later count will also reflect the time spent growing or recovering. Compare an immediate starting estimate with a follow-up measurement using the recorded interval. An increase by the next day is not automatically evidence of a transfer error.