A concentration-response curve, often called a dose-response curve in culture work, plots an endpoint against treatment concentration. A pilot study helps identify a useful concentration range. The main study should include enough concentrations to describe the pattern, including the transition region if a half-response estimate is intended.
Display concentration units and the endpoint on the axes. A logarithmic concentration axis makes equal concentration ratios equally spaced and often clarifies a broad range. Zero concentration cannot be plotted directly on a logarithmic axis; show the vehicle reference separately or identify it in another clear way.
IC₅₀ is the concentration associated with 50% inhibition of a defined response. State which definition is used. An absolute IC₅₀ refers to 50% on a scale normalized to specified assay controls. A relative IC₅₀ refers to the midpoint between the fitted upper and lower plateaus. These values coincide only when the plateaus and normalization allow it.
Figure 13.2. Hypothetical concentration-response and clonogenic survival curves. Left: a curve with upper and lower limits of 100% and 0% crosses 50% at 20 µM. Right: plating-efficiency-corrected survival is shown on a logarithmic vertical axis. Lines illustrate teaching models, not measurements or fitted experimental results. Original plots.
Worked example: locating a half-response
Suppose relative ATP responses at 5, 10, 20, 40, and 80 µM are approximately 80%, 67%, 50%, 33%, and 20%. These hypothetical values suggest a half-control ATP response near 20 µM. The statement must include the cell model, exposure time, assay, and normalization. It is an assay-specific estimate, not a universal toxicity threshold or a clinical dose.
A curve that decreases from a fitted 100% upper plateau to a 40% lower plateau has a relative midpoint of 70%. Its relative IC₅₀ occurs at that midpoint. The concentration where the response reaches 50% of control, if reached, is different. A curve that remains above 50% of control throughout the tested range does not support a directly observed absolute IC₅₀ within that range.
Curve-fitting software estimates parameters from data, often with a sigmoidal model. A plausible-looking curve cannot repair inadequate concentration coverage. Report uncertainty, model choices, and whether the relevant response was bracketed by tested concentrations. Avoid presenting a precise half-response value when the dataset contains only a control and one treatment concentration.
Compare curves only after considering exposure time, cell density, model, medium, and endpoint. A lower IC₅₀ in one assay can reflect a stronger effect on that endpoint, but it does not establish selectivity for diseased cells. A nonmonotonic pattern may be real, or it may reflect solubility, interference, or variable cultures. Examine the observations before forcing them into a standard curve.
This page titled 13.7: Concentration-Response Curves and IC₅₀ was last modified on Wed, 21 Oct 2026 01:36:15 GMT and is shared under a CC BY-NC-SA 4.0 license and was authored, remixed, and/or curated by .