Learn · CERN

Talk53 min

Diagnostics in High Intensity Beams I

Peter Forck · CERN

Watch At CERN

About

Performant beam diagnostics are essential for the successful operation of high-current accelerator facilities, to achieve its design parameters. The usage of standard and advanced beam instrumentation is reviewed. In the first part of the lecture, the methods beam current, transverse profile, and emittance are presented. Invasive diagnostics, such as screens, wire scanners, and grids, may be destroyed by the high beam power; hence, the use of non-invasive types, such as Ionisation Profile Monitors and beam-induced fluorescence, is beneficial. Given the significant non-linear effects present in high-current beams, special emphasis is placed on emittance measurement using tomographic reconstruction methods.

00:00:00 Slide 1

00:01:19 Slide 2

00:01:46 Slide 3

00:03:38 Slide 4

00:06:19 Slide 5

00:07:16 Slide 6

00:08:16 Slide 7

00:08:46 Slide 8

00:09:46 Slide 9

00:09:59 Slide 10

00:10:27 Slide 11

The talk

  1. Diagnostics in High Intensity Beams I 2025-06-19 · 53 min · CERN's player

Credits and licence

Institution
CERN
Department
CAS - CERN Accelerator School
Speaker
Peter Forck
Year
2025
Level
Graduate
Language
English
Source
CERN
Licence
CERN, as CERN states it. CERN's terms
Attribution
© CERN. CERN provides its audiovisual media free of charge for educational and informational use, credited to CERN; this lecture is shown in CERN's own player.
Who can watch
CERN gives no rating. Invisible Network shows it to Teens profiles and older, judged from what the source says about it. How courses are placed