ESS fire- and explosion safety programme - deterministic and probabilistic conditions – case study on acceptance criteria to open smoke hatches in the instrument building.

Fredrik Jörud · CERN

Watch At CERN

About

A number of Swedish acts and ordinances give the basic requirements of facility safety. None of these are tailored for ESS, hence interpretation is required for appropriate application. The Licensee shall as far as reasonable possible, based on existing technical experience and economical and social circumstances, undertake measures to limit 1) production of radioactive waste, 2) release of radioactive substances and 3) exposure to environment from ionizing radiation, ref. Radiation Protection Act (2018:396). Applicable legislative conditions go in to the design. As an example of that is the planning- and building act which requires implementation of: e.g. fire rated partitioning, emergency lights and fire alarm. The defence-in-depth approach (DID) is derived from the radiation protection act by the ESS-0001051 "Protection against fire and explosion". The DID is an important factor of justification to keep fire and explosion at the predicted frequency and consequence. The DID for fire safety sets the deterministic foundation by; 1) preventing the start of fire by housekeeping, to apply proven electrical installation standards etc. 2) quickly detecting and extinguishing the design fires 3) preventing spread of any fire that has not been extinguished. The DID for explosion safety sets the deterministic foundation by 1) preventing explosions by minimizing formation of explosive atmospheres 2) minimizing the risk of an explosion if an explosive atmosphere cannot be avoided 3) implementing design provisions necessary to limit the consequences of an explosion. The Swedish Radiation Safety Authority has released "Special conditions for the ESS facility in Lund", ESS-0018828. The special conditions set numeric acceptance criteria for potential risk of radiation exposure to public: - For the following event classes the reference values, shall apply as a maximum limit for radiological ambient consequences for the facility. Event class: Anticipated events (H2) – 0,1 mSV,…

The talk

  1. ESS fire- and explosion safety programme - deterministic and probabilistic conditions – case study on acceptance criteria to open smoke hatches in the instrument building. 2018-11-26 · 18 min · CERN's player

Credits and licence

Institution
CERN
Department
HSE Workshop
Speaker
Fredrik Jörud
Year
2018
Language
English
Subjects
Engineering
Source
CERN
Licence
CERN, as CERN states it. CERN's terms
Attribution
© CERN. CERN provides its audiovisual media free of charge for educational and informational use, credited to CERN; this lecture is shown in CERN's own player.
Who can watch
CERN gives no rating. Invisible Network shows it to Tweens profiles and older, judged from what the source says about it. How courses are placed