2.2: Load Combinations for Structural Design

Introduction to Aerospace Structures and Materials · LibreTexts

0%

Contents

    Text

    Size
    100%
    Theme
    Typeface
    Line length
    Spacing

    From LibreTexts, under CC BY-NC-SA 4.0, as the source states it; its equations are written in TeX, which the PDF shows typeset. This page at LibreTexts.

    2.2: Load Combinations for Structural Design

    Structures are designed to satisfy both strength and serviceability requirements. The strength requirement ensures the safety of life and property, while the serviceability requirement guarantees the comfortability of occupancy (people) and the aesthetics of the structure. To meet the afore-stated requirements, structures are designed for the critical or the largest load that would act on them. The critical load for a given structure is found by combining all the various possible loads that a structure may carry during its lifetime. Sections 2.3.1 and 2.4.1 of ASCE 7-16 provide the following load combinations for use when designing structures by the Load and Resistance Factor Design (LRFD) and the Allowable Strength Design (ASD) methods.

    For LRFD, the load combinations are as follows:

    1.1.4\(D\)

    2.1.2 \(D+1.6 L+0.5\left(L_{r} \text { or } S \text { or } R\right)\)

    3.1.2\(D+1.6\left(L_{r} \text { or } \text { S or } R\right)+(L \text { or } 0.5 \mathrm{W})\)

    4.1.2\(D+1.0 W+L+0.5\left(L_{r} \text { or } S \text { or } R\right)\)

    5.0.9\(D + 1.0W\)

    For ASD, the load combinations are as follows:

    1.\(D\)

    2.\(D + L\)

    3.\(D + (Lr or S or R)

    4.\(D + 0.75 L + 0.75\left(L_{r} \text { or } S \text { or } R\right)\)

    5.\(D + (0.6 W)\)

    where

    • \(D\) = dead load.
    • \(L\) = live load due to occupancy.
    • \(L_{r}\) = roof live load.
    • \(S\) = snow load.
    • \(R\) = nominal load due to initial rainwater or ice, exclusive of the ponding contributions.
    • \(W\) = wind load.
    • \(E\) = earthquake load.

    Example \(\PageIndex{1}\)

    A floor system consisting of wooden joists spaced 6 ft apart on the center and a tongue and groove wood boarding, as shown in Figure 2.8, supports a dead load (including the weight of the beam and boarding) of 20 psf and a live load of 30 psf. Determine the maximum factored load in lb/ft that each floor joist must support using the LRFD load combinations.

    fig2-8.jpg

    \(Fig. 2.8\). Floor system.

    Solution

    Dead load \(D=(6)(20)=120 \mathrm{lb} / \mathrm{ft}\)

    Live load \(L=(6)(30)=180 \mathrm{lb} / \mathrm{ft}\)

    Determining the maximum factored loads Wu using the LRFD load combinations and neglecting the terms that have no values, yields the following:

    \(W_{u}=(1.4)(120)=168 \mathrm{lb} / \mathrm{ft}\)

    \(W_{u}=(1.2)(120)+(1.6)(180)=288 \mathrm{lb} / \mathrm{ft}\)

    \(W_{u}=(1.2)(120)+(0.5)(180)=234 \mathrm{lb} / \mathrm{ft}\)

    \(W_{u}=(1.2)(120)+(0.5)(180)=234 \mathrm{lb} / \mathrm{ft}\)

    \(W_{u}=(1.2)(120)+(0.5)(180)=234 \mathrm{lb} / \mathrm{ft}\)

    \(W_{u}=(0.9)(120)=108 \mathrm{lb} / \mathrm{ft}\)

    The governing factored load = \(288 \mathrm{lb} / \mathrm{ft}\)

     


    This page titled 2.2: Load Combinations for Structural Design was last modified on Mon, 12 Apr 2021 04:54:05 GMT and is shared under a CC BY-NC-SA 4.0 license and was authored, remixed, and/or curated by René Alderliesten (TU Delft Open) via source content that was edited to the style and standards of the LibreTexts platform.