# Design and qualification of the Mu2e electromagnetic calorimeter radiation monitor system

- Institution: CERN
- Department: Conferences
- Speaker: Franco Spinella
- Year: 2021
- Language: English
- Subjects: Physics, Engineering
- Source: [CERN](https://videos.cern.ch/record/3018148)
- Licence: [CERN](http://copyright.web.cern.ch)
- Who can watch: Tweens profiles and older (sources give no ratings; placed by Invisible Network from the source's own words)

The Mu2e calorimeter and read-out electronics are hosted inside the superconducting magnet cryostat and exposed to an intense flux of ionizing and non-ionizing particles. The performance of a number of components is compromised by radiation damage. This includes the scintillating crystals and silicon photomultipliers (SiPM) whose performance degrades proportionally to both dose and neutrons fluence. The development of a radiation monitor is of vital importance for a reliable detector operation. A system that measures the dose and neutron fluence based on 24 peripheral stations and 4 master units distributed along the detector was built and calibrated..

0:00:00 Slide 1

0:01:59 Slide 2

0:03:57 Slide 3

0:05:56 Slide 4

0:07:54 Slide 5

0:09:53 Slide 6

0:11:51 Slide 7

0:13:49 Slide 8

0:15:48 Slide 9

0:17:46 Slide 10

0:19:45 Slide 11

## Lectures

1. [Design and qualification of the Mu2e electromagnetic calorimeter radiation monitor system](https://invisiblenetwork.ai/learn/cern/3018148/2651a83820dd), 20 min (CERN's player)